Current Search: Chen, Shaowei. (x)
-
-
Title
-
Steel cathodic polarization and calcareous deposit characteristics in deep seawater.
-
Creator
-
Chen, Shaowei., Florida Atlantic University, Hartt, William H., College of Engineering and Computer Science, Department of Ocean and Mechanical Engineering
-
Abstract/Description
-
Field and laboratory ambient and simulated deep seawater sacrificial anode cathodic protection experiments were performed by coupling steel specimens to Al-Zn-Hg anode through an appropriately sized external resistor and thereby permitting a particular level of cathodic protection from freely corroding to overprotection to be simulated. The effects of sea current velocity, surface preparation, initial current density, temperature and hydrostatic pressure upon cathodic polarization and...
Show moreField and laboratory ambient and simulated deep seawater sacrificial anode cathodic protection experiments were performed by coupling steel specimens to Al-Zn-Hg anode through an appropriately sized external resistor and thereby permitting a particular level of cathodic protection from freely corroding to overprotection to be simulated. The effects of sea current velocity, surface preparation, initial current density, temperature and hydrostatic pressure upon cathodic polarization and characteristics of calcareous deposits were investigated in the context of slope parameter and steady-state potential and current density trend. The results revealed that a linear relationship between cathode potential and current density is applicable for design of sacrificial anode cathodic protection systems and analysis of cathodic protection survey data from existing structures both in shallow and deep waters. It was also found that for cathodically polarized steel specimens in ambient (shallow) seawater steady-state cathode potential and current density varied according to a sigmoidal trend that indicates the importance of calcareous deposits in such exposures and demonstrated the utility of rapid polarization. On the other hand, no sigmoidal trend was apparent for field and simulated deep water tests; but instead steady-state current density was constant for potential range between -0.80 and -1.05 v (Ag/AgCl). This disclosed that no particular benefit could be derived from employing rapid polarization in cold water exposures. SEM, EDX and X-ray diffraction analysis revealed that the calcareous deposits formed upon specimens exposed at 5C and ambient pressure or 8.96 MPa laboratory experiments exhibited two layer structures--an outer layer of CaCO3 as aragonite and inner layer of Mg(OH)2 as brucite. The morphology and coverage of the deposits depended on the design slope parameter (initial current density). Field testing results indicated that deposits were also composed of CaCO3 and Mg(OH)2 where the former was calcite. Because of the poor coverage of the deposits formed in the deep water condition, limited current density reduction was noted. These results suggest that a different cp design approach and strategy should be considered for deep, cold seawater compared to that commonly used in shallow water environments.
Show less
-
Date Issued
-
1996
-
PURL
-
http://purl.flvc.org/fcla/dt/12457
-
Subject Headings
-
Seawater corrosion, Cathodic protection, Steel--Corrosion
-
Format
-
Document (PDF)