You are here

Dosimetric Influence of Dose due to the PTV Dose Uniformity on the Critical Organs

Download pdf | Full Screen View

Date Issued:
2023
Abstract/Description:
Dose uniformity in the Planning Target Volume (PTV) can induce a higher-than-expected dose distribution in the nearby critical organs. The goal of this study is to evaluate the influence of the Planning Target volume dose uniformity on the surrounding critical organs (OAR). Ten cases of anonymized patients’ data were selected for our study including: Breast cancer, Brain cancer, Head and Neck cancer, Lung and Prostate calculations of Conformity indices, Biological Effective Doses (BED), Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) were used to calculate the dose distribution in PTV as well as the dose delivered to the surrounding critical organs of each PTV. We assume that the tumors PTVs have homogeneous density as well as the surrounding normal tissue. Conformity indices (CI) for Breast (PTV) are between 1.8 – 1.9, for Brain (PTV) are between 1.6 – 2.0, for Lungs are 1.5 – 1.6, for Prostate are between 0.4 – 0.5, for Head and Neck are 0.3 – 0.4. Dose uniformity in all the PTVs is 1.089 which is a good indication of the quality of treatment delivered to the tumor. TCP is averaging of value of 87.94 and NTCP is 3.4445.
Title: Dosimetric Influence of Dose due to the PTV Dose Uniformity on the Critical Organs.
27 views
13 downloads
Name(s): Yigit, Erdem, author
Pella, Silvia , Thesis advisor
Theodora Leventouri, Theodora Leventouri,, Thesis advisor
Florida Atlantic University, Degree grantor
Department of Physics
Charles E. Schmidt College of Science
Type of Resource: text
Genre: Electronic Thesis Or Dissertation
Date Created: 2023
Date Issued: 2023
Publisher: Florida Atlantic University
Place of Publication: Boca Raton, Fla.
Physical Form: application/pdf
Extent: 59 p.
Language(s): English
Abstract/Description: Dose uniformity in the Planning Target Volume (PTV) can induce a higher-than-expected dose distribution in the nearby critical organs. The goal of this study is to evaluate the influence of the Planning Target volume dose uniformity on the surrounding critical organs (OAR). Ten cases of anonymized patients’ data were selected for our study including: Breast cancer, Brain cancer, Head and Neck cancer, Lung and Prostate calculations of Conformity indices, Biological Effective Doses (BED), Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) were used to calculate the dose distribution in PTV as well as the dose delivered to the surrounding critical organs of each PTV. We assume that the tumors PTVs have homogeneous density as well as the surrounding normal tissue. Conformity indices (CI) for Breast (PTV) are between 1.8 – 1.9, for Brain (PTV) are between 1.6 – 2.0, for Lungs are 1.5 – 1.6, for Prostate are between 0.4 – 0.5, for Head and Neck are 0.3 – 0.4. Dose uniformity in all the PTVs is 1.089 which is a good indication of the quality of treatment delivered to the tumor. TCP is averaging of value of 87.94 and NTCP is 3.4445.
Identifier: FA00014339 (IID)
Degree granted: Thesis (PSM)--Florida Atlantic University, 2023.
Collection: FAU Electronic Theses and Dissertations Collection
Note(s): Includes bibliography.
Subject(s): Radiation dosimetry
Biophysics
Cancer
Persistent Link to This Record: http://purl.flvc.org/fau/fd/FA00014339
Use and Reproduction: Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
Host Institution: FAU