DEVELOPMENT OF A SENSITIVE POLYMERASE CHAIN REACTION (PCR) APPROACH TO DETECT ENTAMOEBA DISPAR IN INDUSTRIAL WASTEWATER

Download pdf | Full Screen View

Date Issued:
2021
Abstract/Description:
Deep injection wells are considered among the most efficient, environmentally-friendly and cost-effective techniques to dispose of wastewater. However, formation of biofilms in the casing pipe can reduce the effective diameter, which in turn, can lower the injectivity of wastewater and ultimately results in injection failure. A class 1 deep injection well located at the Solid Waste Authority of Palm Beach County was revealed to be getting clogged due to the development of a microbial community where Entamoeba dispar, a protozoan species was found to be the abundant microorganism in the biofilm. The injection well is used to discharge industrial wastewater coming from several sources at the facility which are discharged to a collection chamber, known as the wet well, before being disposed down the deep injection well pipe. Prior to design and implementation of a suitable treatment technique to inactivate the protozoan species, it is imperative to reveal the origins of the microorganism coming to the deep injection well. Therefore, the objective of the current research was to develop a technique to identify potential sources of Entamoeba dispar. In this study, samples were collected from the seven sources as well as from the wet well. Initially, a number of onsite and laboratory experiments were conducted to monitor the water quality parameters of the collected samples. In case of microbiological investigations, microscopic analysis was carried out to detect the microorganism in the wastewater specimens followed by polymerase chain reaction (PCR) and gel-electrophoresis assays. In addition, the number of DNA copies in each of the tested samples was determined using the ImageJ app. From the microscopic analysis, no samples were found to be Entamoeba dispar positive. However, PCR and gel electrophoresis tests results indicated that wet well, NEFCO effluent, class 1, REF 1 and groundwater dilution samples were positive and the calculated number of DNA copies were 6545, 6849, 16763, 6351 and 5635 in 100 mL of the wastewater specimens respectively. The PCR technique used in this study is sensitive enough to detect even 4 DNA copies of the target microorganism. All the positive samples have one thing in common, which is they all contain local groundwater from site, indicating a potential source for further investigation.
Title: DEVELOPMENT OF A SENSITIVE POLYMERASE CHAIN REACTION (PCR) APPROACH TO DETECT ENTAMOEBA DISPAR IN INDUSTRIAL WASTEWATER.
84 views
38 downloads
Name(s): Chowdhury, Rakib Ahmed , author
Meeroff, Daniel E., Thesis advisor
Florida Atlantic University, Degree grantor
Department of Civil, Environmental and Geomatics Engineering
College of Engineering and Computer Science
Type of Resource: text
Genre: Electronic Thesis Or Dissertation
Date Created: 2021
Date Issued: 2021
Publisher: Florida Atlantic University
Place of Publication: Boca Raton, Fla.
Physical Form: application/pdf
Extent: 161 p.
Language(s): English
Abstract/Description: Deep injection wells are considered among the most efficient, environmentally-friendly and cost-effective techniques to dispose of wastewater. However, formation of biofilms in the casing pipe can reduce the effective diameter, which in turn, can lower the injectivity of wastewater and ultimately results in injection failure. A class 1 deep injection well located at the Solid Waste Authority of Palm Beach County was revealed to be getting clogged due to the development of a microbial community where Entamoeba dispar, a protozoan species was found to be the abundant microorganism in the biofilm. The injection well is used to discharge industrial wastewater coming from several sources at the facility which are discharged to a collection chamber, known as the wet well, before being disposed down the deep injection well pipe. Prior to design and implementation of a suitable treatment technique to inactivate the protozoan species, it is imperative to reveal the origins of the microorganism coming to the deep injection well. Therefore, the objective of the current research was to develop a technique to identify potential sources of Entamoeba dispar. In this study, samples were collected from the seven sources as well as from the wet well. Initially, a number of onsite and laboratory experiments were conducted to monitor the water quality parameters of the collected samples. In case of microbiological investigations, microscopic analysis was carried out to detect the microorganism in the wastewater specimens followed by polymerase chain reaction (PCR) and gel-electrophoresis assays. In addition, the number of DNA copies in each of the tested samples was determined using the ImageJ app. From the microscopic analysis, no samples were found to be Entamoeba dispar positive. However, PCR and gel electrophoresis tests results indicated that wet well, NEFCO effluent, class 1, REF 1 and groundwater dilution samples were positive and the calculated number of DNA copies were 6545, 6849, 16763, 6351 and 5635 in 100 mL of the wastewater specimens respectively. The PCR technique used in this study is sensitive enough to detect even 4 DNA copies of the target microorganism. All the positive samples have one thing in common, which is they all contain local groundwater from site, indicating a potential source for further investigation.
Identifier: FA00013871 (IID)
Degree granted: Thesis (MS)--Florida Atlantic University, 2021.
Collection: FAU Electronic Theses and Dissertations Collection
Note(s): Includes bibliography.
Subject(s): Entamoeba
Industrial wastewater
Sewage
Polymerase chain reaction
Persistent Link to This Record: http://purl.flvc.org/fau/fd/FA00013871
Use and Reproduction: Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
Use and Reproduction: http://rightsstatements.org/vocab/InC/1.0/
Host Institution: FAU
Is Part of Series: Florida Atlantic University Digital Library Collections.