Development of an Innovative Daily QA System for Pencil-Beam Scanning Proton Therapy
- Date Issued:
- 2020
- Abstract/Description:
- In this work, we have developed a robust daily quality assurance (QA) system for pencil-beam scanning (PBS) dosimetry. A novel phantom and multi-PTV PBS plan were used in conjunction with the Sun Nuclear Daily QA3 multichamber detector array to verify output, range, and spot position. The sensitivity to detect change in these parameters with our designed tests was determined empirically. Associated tolerance levels were established based on these sensitivities and guidelines published in recent American Association of Physics in Medicine (AAPM) task group reports. The output has remained within the 3% tolerance and the range was within ±1mm. Spot position has remained within ±2mm. This daily QA procedure is quick and efficient with the time required for setup and delivery at less than 10 minutes.
Title: | Development of an Innovative Daily QA System for Pencil-Beam Scanning Proton Therapy. |
178 views
103 downloads |
---|---|---|
Name(s): |
Kassel, Maxwell, author Shang, Charles, Thesis advisor Muhammad, Wazir, Thesis advisor Florida Atlantic University, Degree grantor Department of Physics Charles E. Schmidt College of Science |
|
Type of Resource: | text | |
Genre: | Electronic Thesis Or Dissertation | |
Date Created: | 2020 | |
Date Issued: | 2020 | |
Publisher: | Florida Atlantic University | |
Place of Publication: | Boca Raton, Fla. | |
Physical Form: | application/pdf | |
Extent: | 71 p. | |
Language(s): | English | |
Abstract/Description: | In this work, we have developed a robust daily quality assurance (QA) system for pencil-beam scanning (PBS) dosimetry. A novel phantom and multi-PTV PBS plan were used in conjunction with the Sun Nuclear Daily QA3 multichamber detector array to verify output, range, and spot position. The sensitivity to detect change in these parameters with our designed tests was determined empirically. Associated tolerance levels were established based on these sensitivities and guidelines published in recent American Association of Physics in Medicine (AAPM) task group reports. The output has remained within the 3% tolerance and the range was within ±1mm. Spot position has remained within ±2mm. This daily QA procedure is quick and efficient with the time required for setup and delivery at less than 10 minutes. | |
Identifier: | FA00013623 (IID) | |
Degree granted: | Thesis (M.S.)--Florida Atlantic University, 2020. | |
Collection: | FAU Electronic Theses and Dissertations Collection | |
Note(s): | Includes bibliography. | |
Subject(s): |
Proton Therapy Radiation dosimetry Quality assurance |
|
Held by: | Florida Atlantic University Libraries | |
Sublocation: | Digital Library | |
Persistent Link to This Record: | http://purl.flvc.org/fau/fd/FA00013623 | |
Use and Reproduction: | Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder. | |
Use and Reproduction: | http://rightsstatements.org/vocab/InC/1.0/ | |
Host Institution: | FAU | |
Is Part of Series: | Florida Atlantic University Digital Library Collections. |