You are here
FAU Collections » FAU Research Repository » Harbor Branch Oceanographic Institute Collection » HBOI Faculty Contributions
Experimental imaging performance evaluation for alternate configurations of undersea pulsed laser serial imagers
- Date Issued:
- 2011
Title: | Experimental imaging performance evaluation for alternate configurations of undersea pulsed laser serial imagers. |
98 views
18 downloads |
---|---|---|
Name(s): |
Dalgleish, Fraser R., creator Vuorenkoski, Anni K., creator Nootz, G., creator Ouyang, Bing, creator Caimi, F. M., creator |
|
Type of Resource: | text | |
Genre: | Article | |
Issuance: | single unit | |
Date Issued: | 2011 | |
Publisher: | Society of Photo-Optical Instrumentation Engineers | |
Extent: | 12 p. | |
Physical Description: | ||
Language(s): | English | |
Identifier: | 3340796 (digitool), FADT3340796 (IID), fau:6382 (fedora), 10.1117/12.888640 (doi) | |
Note(s): |
This paper examines imaging performance bounds for undersea electro-optic identification (EOID) sensors that use pulsed laser line scanners to form serial images, typically utilizing one laser pulse for each formed image element. The experimental results presented include the use of two distinct imaging geometries; firstly where the laser source and single element optical detector are nearly co-aligned (near monostatic) and secondly where the laser source is deployed on a separate platform positioned closer to the target (bistatic) to minimize source-to-target beam spread, volumetric scatter and attenuation, with the detector being positioned much further from the target. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. This manuscript is an author version and may be cited as: Dalgleish, F. R., Vuorenkoski, A. K., Nootz, G., Ouyang, B., & Caimi, F. M. (2011). Experimental imaging performance evaluation for alternate configurations of undersea pulsed laser serial imagers. In W. W. Hou & R. Arnone (Eds.), Ocean Sensing and Monitoring III, 8030. (pp. 80300B-80310B). Bellingham, Washington: SPIE. doi:10.1117/12.888640 Florida Atlantic University. Harbor Branch Oceanographic Institute contribution #1834. |
|
Subject(s): |
Electrooptics Underwater imaging systems Image Quality Scattering (Physics) Lasers |
|
Persistent Link to This Record: | http://purl.flvc.org/FCLA/DT/3340796 | |
Links: | http://dx.doi.org/10.1117/12.888640 | |
Restrictions on Access: | ©2011 Society of Photo-Optical Instrumentation Engineers | |
Host Institution: | FAU |