You are here
Effect of Polarization on Steel Embedded in Simulated Piling Specimens Evaluated by Critical Chloride Threshold
- Date Issued:
- 2007
- Summary:
- Critical chloride threshold, CT values for initiation of reinforced steel corrosion m mortar typical of Florida coastal bridge substructures were determined in laboratory tests. Previous research has reported CT values that vary by more than an order-of-magnitude, making design life estimation for structures difficult. On this basis, experiments on piling type specimens focused on [Cl-] contamination in the splash zone and coupling of this steel to a large surface area submerged anode. The lower portion of simulated piling was immersed and the region above the waterline periodically sprayed with NaCI solution. Corrosion potential with respect to height above the waterline was monitored. A temporary depolarization method for determining as to whether or not corrosion had initiated is proposed. Chloride distribution at the reinforcement-concrete interface was determined in piling using energy dispersive x-ray analysis and related to height with respect to the waterline. Chloride threshold was related to corrosion potential.
Title: | Effect of Polarization on Steel Embedded in Simulated Piling Specimens Evaluated by Critical Chloride Threshold. |
48 views
20 downloads |
---|---|---|
Name(s): |
Tanner, Russell Hartt, William H., Thesis advisor Florida Atlantic University, Degree grantor College of Engineering and Computer Science Department of Ocean and Mechanical Engineering |
|
Type of Resource: | text | |
Genre: | Electronic Thesis Or Dissertation | |
Date Created: | 2007 | |
Date Issued: | 2007 | |
Publisher: | Florida Atlantic University | |
Place of Publication: | Boca Raton, Fla. | |
Physical Form: | application/pdf | |
Extent: | 106 p. | |
Language(s): | English | |
Summary: | Critical chloride threshold, CT values for initiation of reinforced steel corrosion m mortar typical of Florida coastal bridge substructures were determined in laboratory tests. Previous research has reported CT values that vary by more than an order-of-magnitude, making design life estimation for structures difficult. On this basis, experiments on piling type specimens focused on [Cl-] contamination in the splash zone and coupling of this steel to a large surface area submerged anode. The lower portion of simulated piling was immersed and the region above the waterline periodically sprayed with NaCI solution. Corrosion potential with respect to height above the waterline was monitored. A temporary depolarization method for determining as to whether or not corrosion had initiated is proposed. Chloride distribution at the reinforcement-concrete interface was determined in piling using energy dispersive x-ray analysis and related to height with respect to the waterline. Chloride threshold was related to corrosion potential. | |
Identifier: | FA00012560 (IID) | |
Degree granted: | Thesis (M.S.)--Florida Atlantic University, 2007. | |
Collection: | FAU Electronic Theses and Dissertations Collection | |
Note(s): | College of Engineering and Computer Science | |
Subject(s): |
Reinforced concrete construction Steel, Structural--Corrosion Chlorides Corrosion and anti-corrosives Seawater corrosion |
|
Held by: | Florida Atlantic University Libraries | |
Sublocation: | Digital Library | |
Persistent Link to This Record: | http://purl.flvc.org/fau/fd/FA00012560 | |
Use and Reproduction: | Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder. | |
Use and Reproduction: | http://rightsstatements.org/vocab/InC/1.0/ | |
Host Institution: | FAU | |
Is Part of Series: | Florida Atlantic University Digital Library Collections. |