- One of the major causes of structural repairs worldwide is the corrosion of reinforced concrete structures, such as residential buildings and piers, which are exposed to harsh marine environments. This investigation aims to provide experimental evidence of the fire resistance of corroded high strength reinforced concrete. For this, 14 reinforced concrete beams of three different concrete mix designs (different strengths) were prepared along with concrete cylinders for compression strength testing (ASTM C39). After proper moist curing, all beams were corroded, in two phases, with impressed current, then “crack scored ”for corrosion evaluation, after which half were exposed to fire, also in two phases, following the ASTM E-119-12 time-temperature curve, using a gas kiln. The fire damage was evaluated and compared between phases by using Ultrasonic Pulse Velocity technology. Finally, all specimens were tested for flexural strength by using the third-point loading method (ASTM C78) and the effects of fire on the corroded beams were analyzed according to the level of corrosion.
Title: | Fire resistance of corroded structural concrete. |
229 views
122 downloads |
---|---|---|
Name(s): |
Martinez, Fernando Jose, author Reddy, Dronnadula V., Thesis advisor Florida Atlantic University, Degree grantor College of Engineering and Computer Science Department of Civil, Environmental and Geomatics Engineering |
|
Type of Resource: | text | |
Genre: | Electronic Thesis Or Dissertation | |
Date Created: | 2014 | |
Date Issued: | 2014 | |
Publisher: | Florida Atlantic University | |
Place of Publication: | Boca Raton, Fla. | |
Physical Form: | application/pdf | |
Extent: | 95 p. | |
Language(s): | English | |
Summary: | One of the major causes of structural repairs worldwide is the corrosion of reinforced concrete structures, such as residential buildings and piers, which are exposed to harsh marine environments. This investigation aims to provide experimental evidence of the fire resistance of corroded high strength reinforced concrete. For this, 14 reinforced concrete beams of three different concrete mix designs (different strengths) were prepared along with concrete cylinders for compression strength testing (ASTM C39). After proper moist curing, all beams were corroded, in two phases, with impressed current, then “crack scored ”for corrosion evaluation, after which half were exposed to fire, also in two phases, following the ASTM E-119-12 time-temperature curve, using a gas kiln. The fire damage was evaluated and compared between phases by using Ultrasonic Pulse Velocity technology. Finally, all specimens were tested for flexural strength by using the third-point loading method (ASTM C78) and the effects of fire on the corroded beams were analyzed according to the level of corrosion. | |
Identifier: | FA00004304 (IID) | |
Degree granted: | Thesis (M.S.)--Florida Atlantic University, 2014. | |
Collection: | FAU Electronic Theses and Dissertations Collection | |
Note(s): | Includes bibliography. | |
Subject(s): |
Concrete -- Effect of temperature on Fire resistant materials Reinforced concrete -- Corrosion Thermodynamics |
|
Held by: | Florida Atlantic University Libraries | |
Sublocation: | Digital Library | |
Links: | http://purl.flvc.org/fau/fd/FA00004304 | |
Persistent Link to This Record: | http://purl.flvc.org/fau/fd/FA00004304 | |
Use and Reproduction: | Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder. | |
Use and Reproduction: | http://rightsstatements.org/vocab/InC/1.0/ | |
Host Institution: | FAU | |
Is Part of Series: | Florida Atlantic University Digital Library Collections. |