Summary:
Four concrete piles prestressed with Carbon Fiber Reinforced Plastics were cast, in which two piles were fabricated with CFRP transverse reinforcement. The remaining two were provided with transverse steel spiral reinforcement. The piles were designed according to Florida Department of Transportation (FDOT) guidelines. The Pile Driving Analyzer (PDA) was chosen as the primary data acquisition system for the pile driving due to its mobility, reliability and robustness based on the high frequency excitation. The Pre-driving analysis consisted of several stages. The estimated static bearing capacity of the experimental piles was first calculated followed by SPT sampling at the pile driving site to obtain the soil conditions. The percent skin and toe friction, ultimate capacities, driving system parameters, maximum displacements, energy, integrity, tensions and static capacity were determined prior to pile driving. The piles were then driven and the data from the pile driving compared with the analysis.
Title: Driveability of concrete piles pretensioned with CFRP.
196 views
127 downloads
Name(s): Gemmell, Thomas Scott.
Florida Atlantic University, Degree grantor
Arockiasamy, Madasamy, Thesis advisor
Type of Resource: text
Genre: Electronic Thesis Or Dissertation
Issuance: monographic
Date Issued: 1997
Publisher: Florida Atlantic University
Place of Publication: Boca Raton, Fla.
Physical Form: application/pdf
Extent: 119 p.
Language(s): English
Summary: Four concrete piles prestressed with Carbon Fiber Reinforced Plastics were cast, in which two piles were fabricated with CFRP transverse reinforcement. The remaining two were provided with transverse steel spiral reinforcement. The piles were designed according to Florida Department of Transportation (FDOT) guidelines. The Pile Driving Analyzer (PDA) was chosen as the primary data acquisition system for the pile driving due to its mobility, reliability and robustness based on the high frequency excitation. The Pre-driving analysis consisted of several stages. The estimated static bearing capacity of the experimental piles was first calculated followed by SPT sampling at the pile driving site to obtain the soil conditions. The percent skin and toe friction, ultimate capacities, driving system parameters, maximum displacements, energy, integrity, tensions and static capacity were determined prior to pile driving. The piles were then driven and the data from the pile driving compared with the analysis.
Identifier: 9780591624977 (isbn), 15496 (digitool), FADT15496 (IID), fau:12260 (fedora)
Collection: FAU Electronic Theses and Dissertations Collection
Note(s): College of Engineering and Computer Science
Thesis (M.S.)--Florida Atlantic University, 1997.
Subject(s): Concrete piling
Fiber reinforced plastics
Prestressed concrete
Held by: Florida Atlantic University Libraries
Persistent Link to This Record: http://purl.flvc.org/fcla/dt/15496
Sublocation: Digital Library
Use and Reproduction: Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
Use and Reproduction: http://rightsstatements.org/vocab/InC/1.0/
Host Institution: FAU
Is Part of Series: Florida Atlantic University Digital Library Collections.