You are here
Influence of direct electrical current upon specific volume of mortar in sea water
- Date Issued:
- 1995
- Summary:
- Hollow, cylindrical mortar specimens of 0.4 water-cement ratio were prepared without reinforcement and exposed to flowing natural sea water for periods up to one year. Direct currents of 2, 10 and 50 mA were impressed between a mixed metal-oxide titanium substrate electrode positioned within each of these two zones, with a different electrolyte supply and exhaust for the cylinder core and exterior surface. Linear expansion of the specimens was evaluated as a function of exposure duration from the output of embedded strain gages and from dimensional measurement of cylinder length and diameter. It was found that expansion of specimens exposed to direct current exceeded baseline ones (no current). Also, the expansion was anisotropic in that different magnitudes and trends were apparent for the diameter versus length directions. The expansion under free exposure (no current) was determined to be a function of specimen size and of the direction of measurement relative to the cast specimen face.
Title: | Influence of direct electrical current upon specific volume of mortar in sea water. |
54 views
14 downloads |
---|---|---|
Name(s): |
Le Floch, Anne. Florida Atlantic University, Degree grantor Hartt, William H., Thesis advisor College of Engineering and Computer Science Department of Ocean and Mechanical Engineering |
|
Type of Resource: | text | |
Genre: | Electronic Thesis Or Dissertation | |
Issuance: | monographic | |
Date Issued: | 1995 | |
Publisher: | Florida Atlantic University | |
Place of Publication: | Boca Raton, Fla. | |
Physical Form: | application/pdf | |
Extent: | 140 p. | |
Language(s): | English | |
Summary: | Hollow, cylindrical mortar specimens of 0.4 water-cement ratio were prepared without reinforcement and exposed to flowing natural sea water for periods up to one year. Direct currents of 2, 10 and 50 mA were impressed between a mixed metal-oxide titanium substrate electrode positioned within each of these two zones, with a different electrolyte supply and exhaust for the cylinder core and exterior surface. Linear expansion of the specimens was evaluated as a function of exposure duration from the output of embedded strain gages and from dimensional measurement of cylinder length and diameter. It was found that expansion of specimens exposed to direct current exceeded baseline ones (no current). Also, the expansion was anisotropic in that different magnitudes and trends were apparent for the diameter versus length directions. The expansion under free exposure (no current) was determined to be a function of specimen size and of the direction of measurement relative to the cast specimen face. | |
Identifier: | AAI1376809 (UnM), 15214 (digitool), FADT15214 (IID), fau:11986 (fedora) | |
Collection: | FAU Electronic Theses and Dissertations Collection | |
Note(s): |
College of Engineering and Computer Science Thesis (M.S.E.)--Florida Atlantic University, 1995. |
|
Subject(s): |
Concrete--Deterioration Concrete--Corrosion Seawater corrosion Cathodic protection |
|
Held by: | Florida Atlantic University Libraries | |
Persistent Link to This Record: | http://purl.flvc.org/fcla/dt/15214 | |
Sublocation: | Digital Library | |
Use and Reproduction: | Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder. | |
Use and Reproduction: | http://rightsstatements.org/vocab/InC/1.0/ | |
Host Institution: | FAU | |
Is Part of Series: | Florida Atlantic University Digital Library Collections. |