You are here
Effect of cathodic protection on bond strength between prestressing steel and concrete
- Date Issued:
- 1990
- Summary:
- A series of experiments was performed on prestressed concrete specimens for the purpose of studying the tendency of disbonding between the embedded steel and the concrete due to an impressed cathodic current. The procedure first involved impressing an anodic current until active potentials were recorded along the tendon length. Subsequently, cathodic polarization of the prestressed tendons was affected using a current density of 1 mA/cm^2. The strain variation of the concrete specimens was monitored during these two procedures using gages placed on the top or bottom surface. It was found that for a current density of 1 mA/cm^2 during the 30 day monitoring period the concrete relaxed by an amount equivalent to an 80 percent loss of bond between the tendons and concrete. The implications of this with regard to cathodic protection of prestressed concrete structures and components in actual service are discussed.
Title: | Effect of cathodic protection on bond strength between prestressing steel and concrete. |
82 views
23 downloads |
---|---|---|
Name(s): |
Ducrocq, Luc. Florida Atlantic University, Degree grantor Hartt, William H., Thesis advisor |
|
Type of Resource: | text | |
Genre: | Electronic Thesis Or Dissertation | |
Issuance: | monographic | |
Date Issued: | 1990 | |
Publisher: | Florida Atlantic University | |
Place of Publication: | Boca Raton, Fla. | |
Physical Form: | application/pdf | |
Extent: | 90 p. | |
Language(s): | English | |
Summary: | A series of experiments was performed on prestressed concrete specimens for the purpose of studying the tendency of disbonding between the embedded steel and the concrete due to an impressed cathodic current. The procedure first involved impressing an anodic current until active potentials were recorded along the tendon length. Subsequently, cathodic polarization of the prestressed tendons was affected using a current density of 1 mA/cm^2. The strain variation of the concrete specimens was monitored during these two procedures using gages placed on the top or bottom surface. It was found that for a current density of 1 mA/cm^2 during the 30 day monitoring period the concrete relaxed by an amount equivalent to an 80 percent loss of bond between the tendons and concrete. The implications of this with regard to cathodic protection of prestressed concrete structures and components in actual service are discussed. | |
Identifier: | 14591 (digitool), FADT14591 (IID), fau:11388 (fedora) | |
Collection: | FAU Electronic Theses and Dissertations Collection | |
Note(s): |
College of Engineering and Computer Science Thesis (M.S.E.)--Florida Atlantic University, 1990. |
|
Subject(s): |
Prestressed steel construction Prestressed concrete construction Cathodic protection |
|
Held by: | Florida Atlantic University Libraries | |
Persistent Link to This Record: | http://purl.flvc.org/fcla/dt/14591 | |
Sublocation: | Digital Library | |
Use and Reproduction: | Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder. | |
Use and Reproduction: | http://rightsstatements.org/vocab/InC/1.0/ | |
Host Institution: | FAU | |
Is Part of Series: | Florida Atlantic University Digital Library Collections. |