DATA ACQUISITION AND PROCESSING SYSTEM FOR THE STUDY OF PERIPHERAL VASCULAR DYNAMICS
- Date Issued:
- 1986
- Summary:
- In this study, electrical impedance plethysmograph was used to measure the nonlinear elastic properties of the leg arteries. Two methods were used. In method one, a pressure cuff was wrapped around the lower leg and the recordings were made from under the cuff. Also a second set of recordings were made at a site distal to the cuff, to determine the attenuation of blood pressure pulse by the cuff at cuff pressures above diastolic. In method 2 an Inverter was used and recordings were made from the same segment. Also recordings were made from the upper arm at the heart level to define the blood pressure pulse, that causes the volume change in the leg arteries. A wide range of pressures were used and V-P and compliance curves were calculated with both the methods. In order to improve the accuracy and reduce operator errors, a personal computer based data acquisition and processing system was developed.
Title: | A DATA ACQUISITION AND PROCESSING SYSTEM FOR THE STUDY OF PERIPHERAL VASCULAR DYNAMICS. |
![]() ![]() |
---|---|---|
Name(s): |
CIKIKCI, ISMAIL OGUZ. Florida Atlantic University, Degree grantor Shankar, Ravi, Thesis advisor |
|
Type of Resource: | text | |
Genre: | Electronic Thesis Or Dissertation | |
Issuance: | monographic | |
Date Issued: | 1986 | |
Publisher: | Florida Atlantic University | |
Place of Publication: | Boca Raton, Fla. | |
Physical Form: | application/pdf | |
Extent: | 141 p. | |
Language(s): | English | |
Summary: | In this study, electrical impedance plethysmograph was used to measure the nonlinear elastic properties of the leg arteries. Two methods were used. In method one, a pressure cuff was wrapped around the lower leg and the recordings were made from under the cuff. Also a second set of recordings were made at a site distal to the cuff, to determine the attenuation of blood pressure pulse by the cuff at cuff pressures above diastolic. In method 2 an Inverter was used and recordings were made from the same segment. Also recordings were made from the upper arm at the heart level to define the blood pressure pulse, that causes the volume change in the leg arteries. A wide range of pressures were used and V-P and compliance curves were calculated with both the methods. In order to improve the accuracy and reduce operator errors, a personal computer based data acquisition and processing system was developed. | |
Identifier: | 14338 (digitool), FADT14338 (IID), fau:11145 (fedora) | |
Collection: | FAU Electronic Theses and Dissertations Collection | |
Note(s): |
College of Engineering and Computer Science Thesis (M.S.)--Florida Atlantic University, 1986. |
|
Subject(s): |
Arteries Electronic data processing--Medicine Diagnosis, Noninvasive |
|
Held by: | Florida Atlantic University Libraries | |
Persistent Link to This Record: | http://purl.flvc.org/fcla/dt/14338 | |
Sublocation: | Digital Library | |
Use and Reproduction: | Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder. | |
Use and Reproduction: | http://rightsstatements.org/vocab/InC/1.0/ | |
Host Institution: | FAU | |
Is Part of Series: | Florida Atlantic University Digital Library Collections. |