You are here

PRESSURE FLUCTUATION MEASUREMENT TECHNIQUES IN A CIRCULAR DUCT WITH INCOMPRESSIBLE TURBULENT FLOW (FREQUENCY-WAVENUMBER SPECTRA)

Download pdf | Full Screen View

Date Issued:
1986
Summary:
Turbulent pressure fluctuations and acoustical shock waves formed at pipe discontinuities are the primary source of flow noise. fhe pipe response is excited by the fluctuating forces associated with the turbulent pressure fluctuations. The forcing functions can be determined from the frequency-wavenumber spectrum of the pressure fluctuations. A procedure is developed here to obtain the frequency-wavenumber spectrum due to fully developed turbulent flow. The data analysis procedures developed in this study to analyze the pressure fluctuations provide a good means to determine the frequency-wavenumber spectrum and represent this data in a clear form. Frequency-wavenumber spectra have been obtained for simulated pressure data. In the experimental system designed to collect turbulent pressure data, it was determined that a recessed transducer configuration cannot be used in water pipe flow turbulent pressure fluctuation studies because of the enhanced turbulence created by the upstream holes. Therefore, flush mounted transducers are required.
Title: PRESSURE FLUCTUATION MEASUREMENT TECHNIQUES IN A CIRCULAR DUCT WITH INCOMPRESSIBLE TURBULENT FLOW (FREQUENCY-WAVENUMBER SPECTRA).
112 views
48 downloads
Name(s): DAVIS, HARRY LEE.
Florida Atlantic University, Degree grantor
Cuschieri, Joseph M., Thesis advisor
Type of Resource: text
Genre: Electronic Thesis Or Dissertation
Issuance: monographic
Date Issued: 1986
Publisher: Florida Atlantic University
Place of Publication: Boca Raton, Fla.
Physical Form: application/pdf
Extent: 132 p.
Language(s): English
Summary: Turbulent pressure fluctuations and acoustical shock waves formed at pipe discontinuities are the primary source of flow noise. fhe pipe response is excited by the fluctuating forces associated with the turbulent pressure fluctuations. The forcing functions can be determined from the frequency-wavenumber spectrum of the pressure fluctuations. A procedure is developed here to obtain the frequency-wavenumber spectrum due to fully developed turbulent flow. The data analysis procedures developed in this study to analyze the pressure fluctuations provide a good means to determine the frequency-wavenumber spectrum and represent this data in a clear form. Frequency-wavenumber spectra have been obtained for simulated pressure data. In the experimental system designed to collect turbulent pressure data, it was determined that a recessed transducer configuration cannot be used in water pipe flow turbulent pressure fluctuation studies because of the enhanced turbulence created by the upstream holes. Therefore, flush mounted transducers are required.
Identifier: 14330 (digitool), FADT14330 (IID), fau:11137 (fedora)
Collection: FAU Electronic Theses and Dissertations Collection
Note(s): College of Engineering and Computer Science
Thesis (M.S.E.)--Florida Atlantic University, 1986.
Subject(s): Turbulence--Measurement
Fluid dynamics
Held by: Florida Atlantic University Libraries
Persistent Link to This Record: http://purl.flvc.org/fcla/dt/14330
Sublocation: Digital Library
Use and Reproduction: Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
Use and Reproduction: http://rightsstatements.org/vocab/InC/1.0/
Host Institution: FAU
Is Part of Series: Florida Atlantic University Digital Library Collections.