APPLICATION OF THE ENERGY ACCOUNTANCY EQUATION IN THE INVESTIGATION OF ENERGY TRANSFER IN A THIN WALLED SHELL STRUCTURE

Download pdf | Full Screen View

Date Issued:
1985
Summary:
The Energy Accountancy method is used to describe the response of a system by accounting for the various energy components in a system, that is components describing the input energy, the energy dissipated, and the energy transfered by the system. These components are functions of quantities that can be determined either through measurement or finite element analysis of the system. This concept is used in this study to determine the response of a small diameter pipe containing two different fluids, air and water. The results of this study have shown that the Snergy Accountancy method can be used to describe the response of a thin walled shell structure with good results. It has also been shown in this study that in small diameter pipes the fluid contained by the system can be considered to act as a reactive medium in the response of the structure.
Title: THE APPLICATION OF THE ENERGY ACCOUNTANCY EQUATION IN THE INVESTIGATION OF ENERGY TRANSFER IN A THIN WALLED SHELL STRUCTURE.
84 views
20 downloads
Name(s): SCHAPLEY, RAMON FRANK, II.
Florida Atlantic University, Degree grantor
Dunn, Stanley E., Thesis advisor
Cuschieri, Joseph M., Thesis advisor
College of Engineering and Computer Science
Department of Ocean and Mechanical Engineering
Type of Resource: text
Genre: Electronic Thesis Or Dissertation
Issuance: monographic
Date Issued: 1985
Publisher: Florida Atlantic University
Place of Publication: Boca Raton, Fla.
Physical Form: application/pdf
Extent: 92 p.
Language(s): English
Summary: The Energy Accountancy method is used to describe the response of a system by accounting for the various energy components in a system, that is components describing the input energy, the energy dissipated, and the energy transfered by the system. These components are functions of quantities that can be determined either through measurement or finite element analysis of the system. This concept is used in this study to determine the response of a small diameter pipe containing two different fluids, air and water. The results of this study have shown that the Snergy Accountancy method can be used to describe the response of a thin walled shell structure with good results. It has also been shown in this study that in small diameter pipes the fluid contained by the system can be considered to act as a reactive medium in the response of the structure.
Identifier: 14277 (digitool), FADT14277 (IID), fau:11085 (fedora)
Collection: FAU Electronic Theses and Dissertations Collection
Note(s): College of Engineering and Computer Science
Thesis (M.S.E.)--Florida Atlantic University, 1985.
Subject(s): Force and energy--Analysis
Force and energy--Measurement
Held by: Florida Atlantic University Libraries
Persistent Link to This Record: http://purl.flvc.org/fcla/dt/14277
Sublocation: Digital Library
Use and Reproduction: Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
Use and Reproduction: http://rightsstatements.org/vocab/InC/1.0/
Host Institution: FAU
Is Part of Series: Florida Atlantic University Digital Library Collections.