Validity of the BOD POD(reg) for assessing body composition in male high school athletes
- Date Issued:
- 2006
- Summary:
- The purpose of the present study was to cross-validate the BOD POD (BP) measurements of male high school athletes with those obtained from hydrostatic weighing (HW). Additionally, the percent body fat values measured via near-infrared interactance (NIR), bioelectrical impedance (BIA) and skinfold (SF) were compared to HW to determine the validity of these measures. Thirty male, high school athletes (mean age +/- SD = 15.8 +/- 1.0 yrs) volunteered to have their % fat estimated. The findings from the present study indicated that the NIR and BIA instruments resulted in total error values that were too large to be of practical value (TE = 11.0 and TE = 6.5% fat, respectively). The BP (TE = 3.8% fat) produced acceptable measures (TE < 4.0% fat), but compared to all SF (TE = < 3.5% fat) estimations, BP was higher. These data suggest that the BP can produce acceptable body fat measures for male high school athletes, but is not superior to SF.
Title: | Validity of the BOD POD(reg) for assessing body composition in male high school athletes. |
![]() ![]() |
---|---|---|
Name(s): |
Moon, Jordan R. Florida Atlantic University, Degree grantor O'Kroy, Joseph A., Thesis advisor |
|
Type of Resource: | text | |
Genre: | Electronic Thesis Or Dissertation | |
Issuance: | monographic | |
Date Issued: | 2006 | |
Publisher: | Florida Atlantic University | |
Place of Publication: | Boca Raton, Fla. | |
Physical Form: | application/pdf | |
Extent: | 43 p. | |
Language(s): | English | |
Summary: | The purpose of the present study was to cross-validate the BOD POD (BP) measurements of male high school athletes with those obtained from hydrostatic weighing (HW). Additionally, the percent body fat values measured via near-infrared interactance (NIR), bioelectrical impedance (BIA) and skinfold (SF) were compared to HW to determine the validity of these measures. Thirty male, high school athletes (mean age +/- SD = 15.8 +/- 1.0 yrs) volunteered to have their % fat estimated. The findings from the present study indicated that the NIR and BIA instruments resulted in total error values that were too large to be of practical value (TE = 11.0 and TE = 6.5% fat, respectively). The BP (TE = 3.8% fat) produced acceptable measures (TE < 4.0% fat), but compared to all SF (TE = < 3.5% fat) estimations, BP was higher. These data suggest that the BP can produce acceptable body fat measures for male high school athletes, but is not superior to SF. | |
Identifier: | 9780542739262 (isbn), 13364 (digitool), FADT13364 (IID), fau:10214 (fedora) | |
Note(s): |
College of Education Thesis (M.S.)--Florida Atlantic University, 2006. |
|
Subject(s): |
Athletes Anthropometry--Methodology Human body--Composition--Measurement |
|
Held by: | Florida Atlantic University Libraries | |
Persistent Link to This Record: | http://purl.flvc.org/fcla/dt/13364 | |
Sublocation: | Digital Library | |
Use and Reproduction: | Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder. | |
Use and Reproduction: | http://rightsstatements.org/vocab/InC/1.0/ | |
Host Institution: | FAU | |
Is Part of Series: | Florida Atlantic University Digital Library Collections. |