Current Search: mixed material (x) » Department of Ocean and Mechanical Engineering (x) » Reinforced concrete (x)
View All Items
- Title
- Accelerated curing of concrete with high volume pozzolans - resistivity, diffusivity and compressive strength.
- Creator
- Liu, Yanbo., College of Engineering and Computer Science, Department of Ocean and Mechanical Engineering
- Abstract/Description
-
This investigation presents results of the temperature effect on durability properties (resistivity and diffusivity) and compressive strength of concrete with pozzolans, and the effect of pozzolanic admixtures on microstructure and chemical compositions of concrete pore solution. ... Temperature dependence of electrical resistivity and chloride diffusivity was studied by dynamic temperature tests. Accelerated curing regimes involving curing concrete specimens in 35À C lime water with...
Show moreThis investigation presents results of the temperature effect on durability properties (resistivity and diffusivity) and compressive strength of concrete with pozzolans, and the effect of pozzolanic admixtures on microstructure and chemical compositions of concrete pore solution. ... Temperature dependence of electrical resistivity and chloride diffusivity was studied by dynamic temperature tests. Accelerated curing regimes involving curing concrete specimens in 35À C lime water with different durations were tested. Compressive strength test, resisivity measurement and rapid chloride migration (RCM) tests were performed. A leaching method was used to measure pH and conductivity of concrete pore solution. ... The accelerated curing regimes were found to increase the compressive strength and resistance to chloride ion penetration at short-term and long-term. With the developed correlation between resistivity and migration coefficients, it is possible to employ the resistivity measurement as an alternative or replacement of the RCM test to evaluate resistance of chloride ion penetration of concrete. Pozzolanic admixtures were found to decrease both pH and conductivity of concrete pore solution as the replacement ratio increased. Moreover, the migration coefficients were found to be greatly correlated to the microstructure properties of concrete, such as porosity, formation factor and tortuosity.
Show less - Date Issued
- 2012
- PURL
- http://purl.flvc.org/FAU/3358603
- Subject Headings
- Pavements, Concrete, Additives, Quality control, Waste products as road materials, Reinforced concrete, Corrosion, Testing
- Format
- Document (PDF)
- Title
- Behavior of eccentrically loaded slender concrete columns reinforced with CFRP bars.
- Creator
- Xia, Wei., Florida Atlantic University, Arockiasamy, Madasamy, College of Engineering and Computer Science, Department of Ocean and Mechanical Engineering
- Abstract/Description
-
In a highly corrosive environment, corrosion is the main factor leading to deterioration and eventual failure of conventional reinforced or prestressed concrete structures. Carbon Fiber Reinforced Plastics (CFRP) are considered as an alternative to steel reinforcement due to its excellent corrosion resistance. This investigation was conducted to establish the feasibility of using CFRP cables as reinforcing elements in reinforced concrete columns. Besides investigating durability of CFRP...
Show moreIn a highly corrosive environment, corrosion is the main factor leading to deterioration and eventual failure of conventional reinforced or prestressed concrete structures. Carbon Fiber Reinforced Plastics (CFRP) are considered as an alternative to steel reinforcement due to its excellent corrosion resistance. This investigation was conducted to establish the feasibility of using CFRP cables as reinforcing elements in reinforced concrete columns. Besides investigating durability of CFRP cables in adverse environments (alkali and sea water) experimental and theoretical studies were carried out to study the behavior of CFRP reinforced concrete slender columns under combined axial load and bending moment. Exposure to air, sea water and alkali environments with alternating wet/dry cycles had no adverse effect on the strength of the CFRP cables. The CFRP reinforced concrete columns subjected to eccentric loads exhibited excellent ultimate load capacity. Feasibility of using CFRP cables in the reinforced concrete columns is assessed based on deflections, strains, curvatures, crack distributions, first crack loads and ultimate loads.
Show less - Date Issued
- 1997
- PURL
- http://purl.flvc.org/fcla/dt/15426
- Subject Headings
- Reinforced concrete, Columns, Concrete, Fiber reinforced plastics, Eccentric loads
- Format
- Document (PDF)
- Title
- Chloride thresholds for initiation of corrosion of steel reinforcement in concrete.
- Creator
- Perks, Robert Adam., Florida Atlantic University, Hartt, William H., College of Engineering and Computer Science, Department of Ocean and Mechanical Engineering
- Abstract/Description
-
A study was performed of variables that affect the chloride threshold for corrosion of reinforcement, including pore water alkalinity, water-to-cement ratio, the use of Florida aggregate, and the addition of fly ash. To accomplish this, specimens were subjected to a periodic wet-dry ponding cycle using 15% by weight NaCl solution. Half cell potential and macrocell current measurements were taken to determine the time to corrosion. Upon active corrosion, the specimens were removed from the...
Show moreA study was performed of variables that affect the chloride threshold for corrosion of reinforcement, including pore water alkalinity, water-to-cement ratio, the use of Florida aggregate, and the addition of fly ash. To accomplish this, specimens were subjected to a periodic wet-dry ponding cycle using 15% by weight NaCl solution. Half cell potential and macrocell current measurements were taken to determine the time to corrosion. Upon active corrosion, the specimens were removed from the ponding cycle and dissected. Powder samples were collected from the concrete at the steel depth to ascertain the total chloride concentration. The determination of the pore water pH was attempted using a leaching method. To date only a portion of the specimens have displayed corrosion. The role of cement alkalinity and water-to-cement ratio in affecting corrosion resistance is reported and the results are discussed within the context of designing concrete structures for corrosion resistance.
Show less - Date Issued
- 2000
- PURL
- http://purl.flvc.org/fcla/dt/12721
- Subject Headings
- Steel--Corrosion, Reinforced concrete, Chlorides
- Format
- Document (PDF)
- Title
- Concrete diffusivity and its correlation with chloride deposition rate on concrete exposed to marine environments.
- Creator
- Echevarria, Victor Anthony., College of Engineering and Computer Science, Department of Ocean and Mechanical Engineering
- Abstract/Description
-
The aim of this study was to investigate the diffusion of chloride ions into concrete samples that were exposed in scenarios that simulate the splash, tidal, atmospheric, and immersed portions of a marine structure. To study the atmospheric deposition, the project also investigated the relationship between chloride ion deposition on the wet candle and its accumulation into concrete samples. Results from the wet candle experiment indicated that between 2% and 45% of the chlorides deposited per...
Show moreThe aim of this study was to investigate the diffusion of chloride ions into concrete samples that were exposed in scenarios that simulate the splash, tidal, atmospheric, and immersed portions of a marine structure. To study the atmospheric deposition, the project also investigated the relationship between chloride ion deposition on the wet candle and its accumulation into concrete samples. Results from the wet candle experiment indicated that between 2% and 45% of the chlorides deposited per square meter of exposed area could be found within the concrete samples. After 6 months, slag G1a blocks showed the most resistance to chloride penetration in the tidal and splash simulations. After 10 months of exposure, fly ash samples had the slowest rates of diffusion in the tidal simulation while the fly ash + silica fume samples and the slag samples measured similar rates of diffusion within the tidal zone. After 90 days of curing, cylinders composed of 20% fly ash & 8% silica fume measured the highest average resistivity values and were found to be less vulnerable to chloride ion penetration than the 20% fly ash and the 50% slag concrete through rapid migration tests.
Show less - Date Issued
- 2012
- PURL
- http://purl.flvc.org/FAU/3358557
- Subject Headings
- Reinforced concrete, Construction, Corrosion, Composite reinforced concrete, Corrosion, Testing, Concrete, Fluid dynamics, Concrete, Chemical resistance, Chlorides, Diffusion rate
- Format
- Document (PDF)
- Title
- Concrete surface resistivity profiles along the splash zone on bridge piles exposed to sea water.
- Creator
- Suarez-Solano, Andres M., College of Engineering and Computer Science, Department of Ocean and Mechanical Engineering
- Abstract/Description
-
Prevention of the corrosion of steel reinforcement embedded in concrete is a constant challenge in engineering. A study of concrete surface resistivity versus elevation of partially immersed reinforced concrete structures in a marine splash zone has been developed and correlations made between concrete quality and chloride diffusion, i.e., aggressive ion permeability. A conditioning procedure was developed in which the concrete moisture content is increased by direct contact with fresh water...
Show morePrevention of the corrosion of steel reinforcement embedded in concrete is a constant challenge in engineering. A study of concrete surface resistivity versus elevation of partially immersed reinforced concrete structures in a marine splash zone has been developed and correlations made between concrete quality and chloride diffusion, i.e., aggressive ion permeability. A conditioning procedure was developed in which the concrete moisture content is increased by direct contact with fresh water for several days. The electrical resistivity of concrete is known to be primarily a function of the degree of water saturation. Correlations between field obtained concrete surface resistivity values versus chloride diffusivity, and between normalized resistivity measured on cores obtained from the field versus chloride diffusivity has been established. The resistivity values were measured on structures with different concrete mixes and various ages.
Show less - Date Issued
- 2009
- PURL
- http://purl.flvc.org/FAU/369390
- Subject Headings
- Reinforced concrete, Corrosion, Testing, Reinforcing bars, Properties, Concrete, Permeability, Concrete, Fluid dynamics
- Format
- Document (PDF)
- Title
- Corrosion initiation and propagation on corrosion resistant alloys embedded in concrete by accelerated chloride transport.
- Creator
- Gutierrez Tellez, Francisco., College of Engineering and Computer Science, Department of Ocean and Mechanical Engineering
- Abstract/Description
-
Two duplex stainless steels rebars: UNS32304SS and UNS32101SS, were selected to investigate the corrosion initiation and propagation in reinforced concrete specimens. The investigation is divided in two phases with two different methods to accelerate the transport of chlorides through the concrete and initiate corrosion in a short period of time. After corrosion had initiated and propagated for some time; selected specimens were terminated for visual examination. On specimens selected for...
Show moreTwo duplex stainless steels rebars: UNS32304SS and UNS32101SS, were selected to investigate the corrosion initiation and propagation in reinforced concrete specimens. The investigation is divided in two phases with two different methods to accelerate the transport of chlorides through the concrete and initiate corrosion in a short period of time. After corrosion had initiated and propagated for some time; selected specimens were terminated for visual examination. On specimens selected for autopsy, the rebars in the top row showed corrosion to various degrees. Corrosion had propagated to such extent on the terminated specimens that the specimen showed cracks. Stray current might have caused accelerated corrosion on rebars where corrosion had initiated. Based on chloride concentrations measured at the rebar trace, corrosion initiated: on S32101 rebars on average at 7.9 kg/m3, and S32101 rebars on average at 6.0 kg/m3. The findings suggest that S32304 rebars corroded at a slower than S32101.
Show less - Date Issued
- 2013
- PURL
- http://purl.flvc.org/fcla/dt/3362380
- Subject Headings
- Concrete, Corrosion, Concrete construction, Reinforced concrete, Chemical resistance, Steel, Structural, Corrosion
- Format
- Document (PDF)
- Title
- CORROSION MONITORING AND ANALYSIS OF REINFORCED CONCRETE: CORROSION RESISTANT ALLOYS AFTER LONG TERM EXPOSURE TO CHLORIDES.
- Creator
- Taylor, Redmayne, Presuel-Moreno, Francisco, Florida Atlantic University, Department of Ocean and Mechanical Engineering, College of Engineering and Computer Science
- Abstract/Description
-
Reinforced concrete (RC) is the building block of modern architecture and industry. The failure of which is costly and dangerous. Typically made with carbon steel rebars, corrosion resistant alloys provide an alternative method of delaying failure. Stainless steels, while more expensive than carbon steels, provide excellent corrosion resistance, but less is known about the long term monitoring of corrosion activity for stainless steel than for carbon steel. This study looks at samples...
Show moreReinforced concrete (RC) is the building block of modern architecture and industry. The failure of which is costly and dangerous. Typically made with carbon steel rebars, corrosion resistant alloys provide an alternative method of delaying failure. Stainless steels, while more expensive than carbon steels, provide excellent corrosion resistance, but less is known about the long term monitoring of corrosion activity for stainless steel than for carbon steel. This study looks at samples prepared between 2005 and 2009 using 304SS, 316SS, and 2304SS rebars, as well as SMI and Stelax stainless steel clad carbon steel reinforcements embedded in three different concrete mixes. These selected samples are split into two exposure environments, inside humidity chambers within the laboratory and outdoor exposure. Measurements reported here were made monthly over the course of 250 plus days using the Galvanostatic Pulse method, Electrochemical Impedance Spectroscopy, and a Gecor 8 device. These methods were used to determine corrosion current, isolated corrosion current density, and solution resistance. Corrosion current density values calculated from measurements by the Galvanostatic Pulse and Electrochemical Impedance Spectroscopy method are too small to indicate corrosion, based on value ranges provided by Andrade. However, Gecor 8 corrosion current density values indicate low levels or moderate levels of corrosion for all samples compared to the Andrade’s value ranges. The area used by the Gecor is unknown, so it’s possible this is driving up the measured values.
Show less - Date Issued
- 2023
- PURL
- http://purl.flvc.org/fau/fd/FA00014258
- Subject Headings
- Reinforced concrete, Corrosion resistant alloys, Carbon steel, Corrosion
- Format
- Document (PDF)
- Title
- Driveability of concrete piles pretensioned with CFRP and confinement effects of CFRP hoops in reinforced concrete columns.
- Creator
- Potturu, Rama Kumar., Florida Atlantic University, Arockiasamy, Madasamy, College of Engineering and Computer Science, Department of Ocean and Mechanical Engineering
- Abstract/Description
-
Carbon Fiber Reinforced Plastics has recently has been recognized as an alternative to conventional steel reinforcement in concrete due to its excellent resistance to corrosion. Four rectangular concrete beams and four concrete columns reinforced with CFRP bars were cast for the study of the long term behavior under uniform sustained loading. The beams were simply supported and subjected to uniform sustained loading. The columns were arranged in a steel reaction framework. The beams and...
Show moreCarbon Fiber Reinforced Plastics has recently has been recognized as an alternative to conventional steel reinforcement in concrete due to its excellent resistance to corrosion. Four rectangular concrete beams and four concrete columns reinforced with CFRP bars were cast for the study of the long term behavior under uniform sustained loading. The beams were simply supported and subjected to uniform sustained loading. The columns were arranged in a steel reaction framework. The beams and columns were instrumented and monitored to observe the change in the behavior due to the creep and shrinkage of concrete. An analytical method is developed to predict the long term behavior of CFRP reinforced concrete members. The calculated deformations compare reasonably with the experimental values. A modified equation for the calculation of the long term deflection is proposed for CFRP reinforced concrete beams. A simplified equation for the calculation of the creep coefficient is also proposed.
Show less - Date Issued
- 1997
- PURL
- http://purl.flvc.org/fcla/dt/15507
- Subject Headings
- Fiber reinforced plastics, Concrete piling, Reinforced concrete, Columns, Concrete
- Format
- Document (PDF)
- Title
- ESTIMATION OF THE PHYSICAL PROPERTIES OF CORRODING REBAR IN REINFORCED CONCRETE USING BIOT-STOLL MODEL INVERSION.
- Creator
- Brogden, Matthew, Beaujean, Pierre-Philippe, Florida Atlantic University, Department of Ocean and Mechanical Engineering, College of Engineering and Computer Science
- Abstract/Description
-
The detection of rebar corrosion in reinforced concrete is important due to the high costs of corrosion related damages to infrastructure. One such method of rebar corrosion lies in the use of non-destructive ultrasonic testing. To date, acoustic methods require either the training of an artificial neural network or a theory of acoustic wave propagation. Using a more complete acoustic model such as the Biot-Stoll model avoids algorithm training requirements by directly modeling the acoustic...
Show moreThe detection of rebar corrosion in reinforced concrete is important due to the high costs of corrosion related damages to infrastructure. One such method of rebar corrosion lies in the use of non-destructive ultrasonic testing. To date, acoustic methods require either the training of an artificial neural network or a theory of acoustic wave propagation. Using a more complete acoustic model such as the Biot-Stoll model avoids algorithm training requirements by directly modeling the acoustic environment. A problem with this method lies in the complexity of the model and the selection of free parameters. The problem of parameter selection is addressed by a series of targeted measurements using ultrasonic transducers on a set of existing reinforced concrete samples placed in a saltwater solution. This data can then be analyzed by a non-linear least squares solver to produce a better fit for the acoustic signal.
Show less - Date Issued
- 2022
- PURL
- http://purl.flvc.org/fau/fd/FA00014032
- Subject Headings
- Reinforcing bars--Corrosion, Reinforced concrete, Acoustics, Ultrasonics
- Format
- Document (PDF)
- Title
- Experiments and modeling on resistivity of multi-layer concrete with and without embedded rebar.
- Creator
- Liu, Yanbo., College of Engineering and Computer Science, Department of Ocean and Mechanical Engineering
- Abstract/Description
-
Factors such as water to cement ratio, moisture, mixture, presence and depth of rebar, and dimension of specimens, all of which affect apparent resistivity of concrete, were analyzed by experimental and modeling methods. Cylinder and rectangular prism concrete specimens were used in the experiments exposed in a high moisture room, laboratory room temperature, high humidity and outdoor weather environments. Single rebar and four rebar specimens were used to study the rebar effect on the...
Show moreFactors such as water to cement ratio, moisture, mixture, presence and depth of rebar, and dimension of specimens, all of which affect apparent resistivity of concrete, were analyzed by experimental and modeling methods. Cylinder and rectangular prism concrete specimens were used in the experiments exposed in a high moisture room, laboratory room temperature, high humidity and outdoor weather environments. Single rebar and four rebar specimens were used to study the rebar effect on the apparent resistivity. Modeling analysis was employed to verify and explain the experimental results. Based on the results, concrete with fly ash showed higher resistivity than concrete with just ordinary Portland cement. Rebar presence had a significant effect on the measured apparent resistivity at some of the locations. The results could be used as a guide for field apparent resistivity measurements and provide a quick, more precise and easy way to estimate the concrete quality.
Show less - Date Issued
- 2008
- PURL
- http://purl.flvc.org/FAU/166452
- Subject Headings
- Reinforced concrete, Corrosion, Testing, Reinforcing bars, Properties, Concrete, Quality control
- Format
- Document (PDF)
- Title
- Fire performance of high strength concrete materials and structural concrete.
- Creator
- Liu, Lixian., College of Engineering and Computer Science, Department of Ocean and Mechanical Engineering
- Abstract/Description
-
In recent years, high strength concrete (HSC) is becoming an attractive alternative to traditional normal strength concrete (NSC), and is used in a wide range of applications. With the increased use of HSC, concern has developed regarding the behavior of such concrete in fire. Until now, the fire performance of HSC is not fully understood and more research is needed. Full-scale fire testing is time consuming and expensive, and the real fire scenario is different from the standard fire....
Show moreIn recent years, high strength concrete (HSC) is becoming an attractive alternative to traditional normal strength concrete (NSC), and is used in a wide range of applications. With the increased use of HSC, concern has developed regarding the behavior of such concrete in fire. Until now, the fire performance of HSC is not fully understood and more research is needed. Full-scale fire testing is time consuming and expensive, and the real fire scenario is different from the standard fire. Performance-based assessment methods, including numerical analysis and simplified method, are being accepted in an increasing number of countries. In this dissertation, the fire testing results both of HSC and NSC are presented, performance-based numerical models are developed to study the fire performance of reinforced concrete (RC) members, and simplified calculation methods are proposed to estimate the load capacity of fire-damaged RC columns/beams. A detailed and comprehensive literature review is presented that provides background information on the high temperature behavior of concrete materials and RC members, as well as information on fire performance assessment procedures and objectives. The fire testing results of seven batches of HSC and NSC are presented and discussed. The test results indicated that the post-fire re-curing results in substantial strength and durability recovery, and its extent depends upon the types of concrete, temperature level, and re-curing age. The fire tests also showed that violent explosive reduced the risk of HSC explosive spalling. The surface crack widths were also reduced during the re-curing process, and in most cases, they were found within the maximum limits specified by the American Concrete Institute (ACI) building code., Numerical models are developed herein to investigate the behavior in fire of RC columns and beams. The models have been validated against fire test data available in literature, and used to conduct parametric studies, which focused on the size effect on fire resistance of RC columns, and the effect of concrete cover thickness on fire endurance of RC beams. Simplified calculation methods have been developed to predict the load capacity of fire damaged RC columns/beams. This method is validated by five case studies, including thirty-five RC columns tested by other investigators. The predicted results are compared with the experimental results, and the good agreement indicates the adequacy of the simplified method for practical engineering applications.
Show less - Date Issued
- 2009
- PURL
- http://purl.flvc.org/FAU/369189
- Subject Headings
- Reinforced concrete, Thermodynamics, Concrete, Effect of temperature on, Heat engineering, High strength concrete, Mechanical properties, Concrete, Permeability, Testing
- Format
- Document (PDF)
- Title
- INITIATION AND PROPAGATION OF CORROSION IN DRY-CAST REINFORCED CONCRETE PIPES WITH ENVIRONMENTAL EFFECTS.
- Creator
- Balasubramanian, Hariharan, Presuel-Moreno, Francisco, Florida Atlantic University, College of Engineering and Computer Science, Department of Ocean and Mechanical Engineering
- Abstract/Description
-
This research was conducted to better understand the corrosion propagation stage on dry-cast reinforced concrete pipes (DCRCPs) while exposed to high moisture conditions and chlorides. Corrosion initiation and propagation were studied in instrumented specimens obtained from segments of dry-cast reinforced concrete pipes. All specimens were subjected to accelerated chloride transport by the application of an electric field. Corrosion of the steel wire mesh initiated after a few days to a few...
Show moreThis research was conducted to better understand the corrosion propagation stage on dry-cast reinforced concrete pipes (DCRCPs) while exposed to high moisture conditions and chlorides. Corrosion initiation and propagation were studied in instrumented specimens obtained from segments of dry-cast reinforced concrete pipes. All specimens were subjected to accelerated chloride transport by the application of an electric field. Corrosion of the steel wire mesh initiated after a few days to a few months rather than several years. The specimens were then transferred to high moisture environments (immersed in water, high humidity and/or covered with wet sand) during the corrosion propagation stage. Reinforcement potentials, linear polarization resistance (LPR) and Electrochemical Impedance Spectroscopy (EIS) measurements were carried out periodically. During the propagation stage in different exposures, reinforcement eventually reached negative potentials values (< –-0.55 Vsce), which suggest mass transfer limitations. These specimens showed no visual signs of corrosion such as cracks or corrosion products except the ones exposed to high humidity and laboratory environments; where some corrosion products have reached the concrete surface. Moreover, the apparent corrosion rate values obtained suggest high corrosion rates. No crack appearance on specimens exposed to other conditions could be explained by the porosity of the specimens; the corrosion products moved into saturated pores. It is speculated that although there might be mass transfer limitations present, the current demanded by the anode is being balanced by a larger cathode area due to macrocell effects since the high moisture conditions likely reduced the concrete resistivity and increased the throwing power. The corrected polarization resistance (Rc) was calculated by subtracting the solution resistance from the apparent polarization resistance measured. The Rc values measured over time were used to obtain the calculated mass loss (using Faraday’s Law). Most specimens were forensically analyzed and the measured mass loss compared to the calculated mass loss. The forensic examination includes the measurement of the actual corroding areas. The measured corroding areas were used to obtain corrosion current density (icorr) values. A comparison was made of the calculated corrosion current densities obtained using the linear polarization resistance method (LPR) and the extrapolation method from cyclic polarization tests. It was evident that most of the specimens’ corrosion rates were significantly high. The corrosion products filled the wet-pores inside the concrete and provide an explanation for no cracks or corrosion bleed outs being visually observed on the specimens.
Show less - Date Issued
- 2019
- PURL
- http://purl.flvc.org/fau/fd/FA00013182
- Subject Headings
- Reinforced concrete, Corrosion, Environmental effects
- Format
- Document (PDF)
- Title
- Optimized Parameters Fitting of a Poro-Elastic Acoustic Model with Ultrasonic Measurements for the Monitoring of Corroding Rebar in Reinforced Concrete.
- Creator
- Shaffer, Samuel, Beaujean, Pierre-Philippe, Florida Atlantic University, Department of Ocean and Mechanical Engineering, College of Engineering and Computer Science
- Abstract/Description
-
Traditional techniques of observing cracking within reinforced structures can be invasive, leading to an increased risk of added corrosion to structures already undergoing corrosive processes. The research presented in this document improves upon a nondestructive method for detecting early crack formation in reinforced concrete. This method includes using acoustic signaling to add a layer of salt water between the sensor and analyzed sample. Following the collection of surface and rebar echo...
Show moreTraditional techniques of observing cracking within reinforced structures can be invasive, leading to an increased risk of added corrosion to structures already undergoing corrosive processes. The research presented in this document improves upon a nondestructive method for detecting early crack formation in reinforced concrete. This method includes using acoustic signaling to add a layer of salt water between the sensor and analyzed sample. Following the collection of surface and rebar echo responses, an adapted version of the novel Biot-Stoll method is used to model sound propagation for poro-elastic mediums. Testing of model parameters and variables has improved the root mean square error (RMSE) by up to 63.7% when studying the full signal, and up to 62.6% for the rebar echo locations. These improvements signify better curve fitting between simulated and measured responses, which lead to increased accuracy in the model parameter outputs.
Show less - Date Issued
- 2023
- PURL
- http://purl.flvc.org/fau/fd/FA00014265
- Subject Headings
- Reinforced concrete, Reinforcing bars--Corrosion, Ultrasonic testing
- Format
- Document (PDF)
- Title
- Synthetic Fiber Reinforced Concrete in Marine Environments and Indirect Tension Test.
- Creator
- Flaherty, Ryan, Presuel-Moreno, Francisco, Florida Atlantic University, College of Engineering and Computer Science, Department of Ocean and Mechanical Engineering
- Abstract/Description
-
An experiment was conducted to evaluate the durability, toughness, and strength of Synthetic Fiber Reinforced Concrete after being immersed in five separate environments for one year at FAU SeaTech. The specimens were molded and reinforced with two-inch Polypropylene/Polyethylene Fibers in a concrete aggregate matrix and were cut into identical sizes. Some of these environments had accelerated parameters meant to increase degradation to simulate longevity and imitate harsh environments or...
Show moreAn experiment was conducted to evaluate the durability, toughness, and strength of Synthetic Fiber Reinforced Concrete after being immersed in five separate environments for one year at FAU SeaTech. The specimens were molded and reinforced with two-inch Polypropylene/Polyethylene Fibers in a concrete aggregate matrix and were cut into identical sizes. Some of these environments had accelerated parameters meant to increase degradation to simulate longevity and imitate harsh environments or seawater conditions. The environments consisted of: a high humidity locker (ideal conditions), submerged in the Intracoastal Waterway (FAU barge), seawater immersion, a wet and dry seawater immersion simulating a splash/tidal zone, and another in low pH seawater. The latter three were in an elevated temperature room (87-95°F) which produced more degradative properties. The specimens were monitored and the environments were controlled. The specimens were then evaluated using the IDT test method using force to initiate first-cracking and post-cracking behaviors.
Show less - Date Issued
- 2018
- PURL
- http://purl.flvc.org/fau/fd/FA00013029
- Subject Headings
- Reinforced concrete, Fiber-reinforced concrete--Testing, Synthetic fibers
- Format
- Document (PDF)
- Title
- SYNTHETIC FIBER REINFORCED CONCRETE PERFORMANCE AFTER PROLONGED ENVIRONMENTAL EXPOSURE UTILIZING THE MODIFIED INDIRECT TENSILE TEST.
- Creator
- Ellis, Spencer G., Presuel-Moreno, Francisco, Florida Atlantic University, Department of Ocean and Mechanical Engineering, College of Engineering and Computer Science
- Abstract/Description
-
In order to study the mechanical performance of dry-cast synthetic fiber reinforced concrete (SynFRC), samples of varying geometry, fiber content, and environmental exposure were developed and tested using the modified indirect tensile test. The samples created consisted of three different thicknesses (with two different geometries), and six different fiber contents that differed in either type, or quantity, of fibers. Throughout the duration of this research, procedures for inflicting...
Show moreIn order to study the mechanical performance of dry-cast synthetic fiber reinforced concrete (SynFRC), samples of varying geometry, fiber content, and environmental exposure were developed and tested using the modified indirect tensile test. The samples created consisted of three different thicknesses (with two different geometries), and six different fiber contents that differed in either type, or quantity, of fibers. Throughout the duration of this research, procedures for inflicting detrimental materials into the concrete samples were employed at a number of different environments by implementing accelerated rates of deterioration using geometric adjustments, increased temperature exposure, wetting/drying cycles, and preparation techniques. The SynFRC samples studied were immersed in a wide range of environments including: the exposure of samples to high humidity and calcium hydroxide environments, which served at the control group, while the sea water, low pH, and barge conditioning environments were used to depict the real world environments similar to what would be experienced in the Florida ecosystem. As a result of this conditioning regime, the concrete was able to imitate the real-world effects that the environments would have inflicted if exposed for long durations after an exposure period of only 20-24 months. Having adequately conditioned the samples in their respective environments, they were then tested (and forensically investigated) using the modified indirect tensile testing method to gather data regarding each sample’s toughness and load handling capability. By analyzing the results from each sample, the toughness was calculated by taking the area under the force displacement curve. From these toughness readings it was found that possible degradation occurred between the fiber-matrix interface of some of the concrete samples conditioned in the Barge environment. From these specimens that were immersed in the barge environment, a handful of them exhibited multiple episodes of strain softening characteristics within their force displacement curves. In regard to the fibers used within the samples, the PVA fibers tended to pull off more while the Tuff Strand SF fibers had the highest tendency to break (despite some of the fibers showing similar pull off and breaking failure characteristics). When it comes to the overall thickness of the sample, there was clear correlation between the increase in size and the increase in sample toughness, however the degree to which it correlates varies from sample to sample.
Show less - Date Issued
- 2020
- PURL
- http://purl.flvc.org/fau/fd/FA00013466
- Subject Headings
- Reinforced concrete, Fiber-reinforced concrete--Testing, Reinforced concrete--Mechanical properties, Tensile Strength, Concrete—Environmental testing
- Format
- Document (PDF)