- Title
- Improved Methodology of Static HDMLC Virtual Cone based Rapid Arcs for Stereotactic Ablative Radiotherapy.
- Creator
- Stevens, Ryan, Shang, Charles, Muhammad, Wazir, Florida Atlantic University, Department of Physics, Charles E. Schmidt College of Science
- Abstract/Description
-
Physical cones equipped on GammaKnife, Cyberknife, and C-arm linacs have been the standard practice in Stereotactic Ablative Radiotherapy (SART) for small intracranial lesions, such as treating trigeminal or glossopharyngeal neuralgia targets. The advancement of high-definition multi-leaf collimators (HDMLC), treatment planning systems, and small field dosimetry now allows for treatment without the need for an auxiliary mounted physical cone. This treatment type uses the “virtual cone”, a...
Show morePhysical cones equipped on GammaKnife, Cyberknife, and C-arm linacs have been the standard practice in Stereotactic Ablative Radiotherapy (SART) for small intracranial lesions, such as treating trigeminal or glossopharyngeal neuralgia targets. The advancement of high-definition multi-leaf collimators (HDMLC), treatment planning systems, and small field dosimetry now allows for treatment without the need for an auxiliary mounted physical cone. This treatment type uses the “virtual cone”, a permanent high-definition MLC, arrangement to deliver “very small fields” with comparable spherical dose distributions to physical cones. The virtual cone therapy, on a Varian Edge™ linac using multiple non-coplanar arcs with static HDMLCs, is a comparable technique that can be used to treat small intracranial neuralgia or other small lesions. In this investigation, two flattening filter free (FFF) photon beams, 6MV FFF and 10MV FFF, were tested for optimal delivery and safety conditions for treating intracranial lesions. The virtual cone method on a Varian Edge™ Linear accelerator using rapid arc stereotactic radiosurgery was used to treat cranial neuralgia for chronic pain for six patients. Absolute dose, relative dose measurements, and monitor units were the main characteristics that were examined to decide which energy was the best for treatment. Source-to-axis distances (SAD) of 100cm measurements were taken at depths of 10cm and 5cm, respectively.
Show less - Date Issued
- 2020
- PURL
- http://purl.flvc.org/fau/fd/FA00013630
- Subject Headings
- Radiotherapy, Radiation dosimetry, Stereotaxic Techniques
- Format
- Document (PDF)
- Title
- A characterization of the LAP Aquarius Phantom for external LAP laser alignment and magnetic resonance geometric distortion verification for stereotactic radiation surgery patient simulation.
- Creator
- Vergara, Daniel, Charles E. Schmidt College of Science, Department of Physics
- Abstract/Description
-
The Thesis explores additional applications of LAP's Aquarius external laser alignment verification Phantom by examining geometric accuracy of magnetic resonance images commonly used for planning intracranial stereotactic radiation surgery (ICSRS) cases. The scans were performed with MRI protocols used for ICSRS, and head and neck diagnosis, and their images fused to computerized tomographic (CT) images. The geometric distortions (GDs) were measured against the CT in all axial, sagittal, and...
Show moreThe Thesis explores additional applications of LAP's Aquarius external laser alignment verification Phantom by examining geometric accuracy of magnetic resonance images commonly used for planning intracranial stereotactic radiation surgery (ICSRS) cases. The scans were performed with MRI protocols used for ICSRS, and head and neck diagnosis, and their images fused to computerized tomographic (CT) images. The geometric distortions (GDs) were measured against the CT in all axial, sagittal, and coronal directions at different levels. Using the Aquarius Phantom, one is able to detect GD in ICSRS planning MRI acquisitions, and align the external LAP patient alignment lasers, by following the LAP QA protocol. GDs up to about 2 mm are observed at the distal regions of the longitudinal axis in the SRS treatment planning MR images. Based on the results, one may recommend the use of the Aquarius Phantom to determine if margins should be included for SRS treatment planning.
Show less - Date Issued
- 2012
- PURL
- http://purl.flvc.org/FAU/3352878
- Subject Headings
- Radiotherapy, Techniques, Medical physics, Imaging systems in medicine, Tomographic images, Computerized axial tomography
- Format
- Document (PDF)