Current Search: Proton beams. (x)
View All Items
- Title
- Nuclear Halo Effect and Field Size Factor for Pencil-Beam Scanning Proton Therapy.
- Creator
- Beqiri, Atdhe, Shang, Charles, Muhammad, Wazir, Florida Atlantic University, Department of Physics, Charles E. Schmidt College of Science
- Abstract/Description
-
In proton therapy systems with pencil-beam scanning, output of Halo effect is not necessarily included in Treatment Planning System (TPS). Halo effect (low-intensity tail) can significantly affect a patient’s dose distribution. The output of this dose depends on the field size being irradiated. Although much research has been made to investigate such relation to the field size, the number of reports on dose calculations including the halo effect is small. In this work we have investigated the...
Show moreIn proton therapy systems with pencil-beam scanning, output of Halo effect is not necessarily included in Treatment Planning System (TPS). Halo effect (low-intensity tail) can significantly affect a patient’s dose distribution. The output of this dose depends on the field size being irradiated. Although much research has been made to investigate such relation to the field size, the number of reports on dose calculations including the halo effect is small. In this work we have investigated the Halo effect, including field size factor, target depth factor, and air gaps with a range shifter for a Varian ProBeam. Dose calculations created on the Eclipse Treatment Planning System (vs15.6 TPS) are compared with plane-parallel ionization chambers (PTW Octavius 1500) measurements using PCS and AcurosPT MC model in different isocenters: 5cm, 10cm, and 20cm. We find that in AcurosPT algorithm deviations range between -7.53% (for 2cm field in 25cm air gap with range shifter) up to +7.40% (for 20cm field in 15cm air gap with range shifter). Whereas, in PCS algorithm the deviations are -2.07% (for 20x20cm field in open conditions) to -6.29% (for 20x20cm field in 25cm air gap with range shifter).
Show less - Date Issued
- 2021
- PURL
- http://purl.flvc.org/fau/fd/FA00013788
- Subject Headings
- Proton Therapy, Proton beams, Radiotherapy
- Format
- Document (PDF)
- Title
- Validation of a Monte Carlo dose calculation algorithm for clinical electron beams in the presence of phantoms with complex heterogeneities.
- Creator
- Enright, Shayla Landfair, Pella, Silvia, Florida Atlantic University, Charles E. Schmidt College of Science, Department of Physics
- Abstract/Description
-
The purpose of this thesis is to validate the Monte Carlo algorithm for electron radiotherapy in the Eclipse™ treatment planning system (TPS), and to compare the accuracy of the Electron Monte Carlo algorithm (eMC) to the Pencil Beam algorithm (PB) in Eclipse™. Dose distributions from GafChromic™ EBT3 film measurements were compared to dose distributions from eMC and PB treatment plans. Measurements were obtained with 6MeV, 9MeV, and 12MeV electron beams at various depths. A 1 cm thick solid...
Show moreThe purpose of this thesis is to validate the Monte Carlo algorithm for electron radiotherapy in the Eclipse™ treatment planning system (TPS), and to compare the accuracy of the Electron Monte Carlo algorithm (eMC) to the Pencil Beam algorithm (PB) in Eclipse™. Dose distributions from GafChromic™ EBT3 film measurements were compared to dose distributions from eMC and PB treatment plans. Measurements were obtained with 6MeV, 9MeV, and 12MeV electron beams at various depths. A 1 cm thick solid water template with holes for bone-like and lung-like plugs was used to create assorted configurations and heterogeneities. Dose distributions from eMC plans agreed better with the film measurements based on gamma analysis. Gamma values for eMC were between 83%-99%, whereas gamma values for PB treatment plans were as low as 38.66%. Our results show that using the eMC algorithm will improve dose accuracy in regions with heterogeneities and should be considered over PB.
Show less - Date Issued
- 2014
- PURL
- http://purl.flvc.org/fau/fd/FA00004192
- Subject Headings
- Electron beams -- Therapeutic use, Image guided radiotherapy, Monte Carlo method, Proton beams -- Therapeutic use, Radiation dosimetry, Radiotherapy, High energy
- Format
- Document (PDF)
- Title
- Exploring appropriate offset values for pencil beam and Monte Carlo dose optimization in lung stereotactic body radiotherapy encompassing the effects of respiration and tumor location.
- Creator
- Evans, Grant, Shang, Charles, Florida Atlantic University, Charles E. Schmidt College of Science, Department of Physics
- Abstract/Description
-
Evaluation of dose optimization using the Pencil Beam (PB) and Monte Carlo (MC) algorithms may allow physicists to apply dosimetric offsets to account for inaccuracies of the PB algorithm for lung cancer treatment with Stereotactic Body Radiotherapy (SBRT). 20 cases of Non-Small Cell Lung Cancer (NSCLC) were selected. Treatment plans were created with Brainlab iPlanDose® 4.1.2. The D97 of the Planning Target Volume (PTV) was normalized to 50 Gy on the Average Intensity Projection (AIP) using...
Show moreEvaluation of dose optimization using the Pencil Beam (PB) and Monte Carlo (MC) algorithms may allow physicists to apply dosimetric offsets to account for inaccuracies of the PB algorithm for lung cancer treatment with Stereotactic Body Radiotherapy (SBRT). 20 cases of Non-Small Cell Lung Cancer (NSCLC) were selected. Treatment plans were created with Brainlab iPlanDose® 4.1.2. The D97 of the Planning Target Volume (PTV) was normalized to 50 Gy on the Average Intensity Projection (AIP) using the fast PB and compared with MC. This exact plan with the same beam Monitor Units (MUs) was recalculated over each respiratory phase. The results show that the PB algorithm has a 2.3-2.4% less overestimation at the maximum exhalation phase than the maximum inhalation phase when compared to MC. Significantly smaller dose difference between PB and MC is also shown in plans for peripheral lesions (7.7 ± 0.7%) versus central lesions (12.7±0.8%)(p< 0.01).
Show less - Date Issued
- 2014
- PURL
- http://purl.flvc.org/fau/fd/FA00004105, http://purl.flvc.org/fau/fd/FA00004105
- Subject Headings
- Drug development -- Computer simulation, Image guided radiation therapy, Lung cancer -- Treatment, Monte Carlo method, Proton beams, Transport theory
- Format
- Document (PDF)
- Title
- A dosimetric study of a heterogeneous phantom for lung stereotactic body radiation therapy comparing Monte Carlo and pencil beam calculations to dose distributions measured with a 2-d diode array.
- Creator
- Curley, Casey Michael, Ouhib, Zoubir, Florida Atlantic University, Charles E. Schmidt College of Science, Department of Physics
- Abstract/Description
-
Monte Carlo (MC) and Pencil Beam (PB) calculations are compared to their measured planar dose distributions using a 2-D diode array for lung Stereotactic Body Radiation Therapy (SBRT). The planar dose distributions were studied for two different phantom types: an in-house heterogeneous phantom and a homogeneous phantom. The motivation is to mimic the human anatomy during a lung SBRT treatment and incorporate heterogeneities into the pre-treatment Quality Assurance process, where measured and...
Show moreMonte Carlo (MC) and Pencil Beam (PB) calculations are compared to their measured planar dose distributions using a 2-D diode array for lung Stereotactic Body Radiation Therapy (SBRT). The planar dose distributions were studied for two different phantom types: an in-house heterogeneous phantom and a homogeneous phantom. The motivation is to mimic the human anatomy during a lung SBRT treatment and incorporate heterogeneities into the pre-treatment Quality Assurance process, where measured and calculated planar dose distributions are compared before the radiation treatment. Individual and combined field dosimetry has been performed for both fixed gantry angle (anterior to posterior) and planned gantry angle delivery. A gamma analysis has been performed for all beam arrangements. The measurements were obtained using the 2-D diode array MapCHECK 2™.
Show less - Date Issued
- 2015
- PURL
- http://purl.flvc.org/fau/fd/FA00004360
- Subject Headings
- Cancer -- Radiotherapy, Drug development -- Computer simulation, Image guided radiation therapy, Ion bombardment, Lung cancer -- Treatment, Medical physics, Monte Carlo method, Proton beams
- Format
- Document (PDF)
- Title
- Phantom Study Incorporating A Diode Array Into The Treatment Planning System For Patient-Specific Quality Assurance.
- Creator
- Curley, Casey Michael, Leventouri, Theodora, Ouhib, Zoubir, Florida Atlantic University, Charles E. Schmidt College of Science, Department of Physics
- Abstract/Description
-
The purpose of this research is to accurately match the calculation environment, i.e. the treatment planning system (TPS) with the measurement environment (using a 2-D diode array) for lung Stereotactic Body Radiation Therapy (SBRT) patient-specific quality assurance (QA). Furthermore, a new phantom was studied in which the 2-D array and heterogeneities were incorporated into the patient-specific QA process for lung SBRT. Dual source dual energy computerized tomography (DSCT) and single...
Show moreThe purpose of this research is to accurately match the calculation environment, i.e. the treatment planning system (TPS) with the measurement environment (using a 2-D diode array) for lung Stereotactic Body Radiation Therapy (SBRT) patient-specific quality assurance (QA). Furthermore, a new phantom was studied in which the 2-D array and heterogeneities were incorporated into the patient-specific QA process for lung SBRT. Dual source dual energy computerized tomography (DSCT) and single energy computerized tomography (SECT) were used to model phantoms incorporating a 2-D diode array into the TPS. A water-equivalent and a heterogeneous phantom (simulating the thoracic region of a patient) were studied. Monte Carlo and pencil beam dose distributions were compared to the measured distributions. Composite and individual fields were analyzed for normally incident and planned gantry angle deliveries. The distributions were compared using γ-analysis for criteria 3% 3mm, 2% 2mm, and 1% 1mm. The Monte Carlo calculations for the DSCT modeled phantoms (incorporating the array) showed an increase in the passing percentage magnitude for 46.4 % of the fields at 3% 3mm, 85.7% at 2% 2mm, and 92.9% at 1% 1mm. The Monte Carlo calculations gave no agreement for the same γ-analysis criteria using the SECT. Pencil beam calculations resulted in lower passing percentages when the diode array was incorporated in the TPS. The DSCT modeled phantoms (incorporating the array) exhibited decrease in the passing percentage magnitude for 85.7% of the fields at 3% 3mm, 82.1% at 2% 2mm, and 71.4% at 1% 1mm. In SECT modeled phantoms (incorporating the array), a decrease in passing percentage magnitude were found for 92.9% of the fields at 3% 3mm, 89.3% at 2% 2mm, and 82.1% at 1% 1mm. In conclusion, this study demonstrates that including the diode array in the TPS results in increased passing percentages when using a DSCT system with a Monte Carlo algorithm for patient-specific lung SBRT QA. Furthermore, as recommended by task groups (e.g. TG 65, TG 101, TG 244) of the American Association of Physicists in Medicine (AAPM), pencil beam algorithms should be avoided in the presence of heterogeneous materials, including a diode array.
Show less - Date Issued
- 2016
- PURL
- http://purl.flvc.org/fau/fd/FA00004744, http://purl.flvc.org/fau/fd/FA00004744
- Subject Headings
- Cancer--Radiotherapy., Lungs--Cancer--Treatment., Monte Carlo method., Proton beams., Image-guided radiation therapy., Ion bombardment., Medical physics.
- Format
- Document (PDF)