Current Search: Calibration (x)
View All Items
- Title
- A novel closed-loop approach for identification of manipulator kinematic parameters.
- Creator
- Wang, Yuemin., Florida Atlantic University, Huang, Ming Z., College of Engineering and Computer Science, Department of Computer and Electrical Engineering and Computer Science
- Abstract/Description
-
During the manufacture of industrial robots, differences between actual and nominal linkage parameters occur. Thus, when a robot system attempts to perform a desired task using nominal parameter based planning schemes, it usually performs the task quite differently from the desired one. A method for automatically determining the differences between nominal and actual parameter models, namely calibration, is presented in this thesis. The method features a simple and efficient measurement...
Show moreDuring the manufacture of industrial robots, differences between actual and nominal linkage parameters occur. Thus, when a robot system attempts to perform a desired task using nominal parameter based planning schemes, it usually performs the task quite differently from the desired one. A method for automatically determining the differences between nominal and actual parameter models, namely calibration, is presented in this thesis. The method features a simple and efficient measurement scheme using an instrumented articulated linkage. The basis of parameter identification approach is similar to that of closed-loop mechanism syntheses. Jacobian formulation using a vector cross product method with mixed choices of kinematic model for coordinate system representation is adopted. Effectiveness of this method and factors affecting the calibration are examined using simulation. A complete design of the measurement device, both electrical and mechanical, is also presented.
Show less - Date Issued
- 1991
- PURL
- http://purl.flvc.org/fcla/dt/14732
- Subject Headings
- Calibration, Robots, Industrial--Calibration
- Format
- Document (PDF)
- Title
- Camera calibration techniques.
- Creator
- Xu, Xuan., Florida Atlantic University, Roth, Zvi S., Zhuang, Hanqi, College of Engineering and Computer Science, Department of Computer and Electrical Engineering and Computer Science
- Abstract/Description
-
In order to facilitate the implementation of RAC-based camera calibration technique, several issues are addressed in this thesis. First, a straightforward extension of the RAC-based camera calibration technique to the case of unknown camera specifications is given. Second, to speed up the calibration process and reduce numerical difficulties, a simplified RAC-based method is presented. The simplified RAC-based method provides a closed-form solution to the camera calibration problem. Third,...
Show moreIn order to facilitate the implementation of RAC-based camera calibration technique, several issues are addressed in this thesis. First, a straightforward extension of the RAC-based camera calibration technique to the case of unknown camera specifications is given. Second, to speed up the calibration process and reduce numerical difficulties, a simplified RAC-based method is presented. The simplified RAC-based method provides a closed-form solution to the camera calibration problem. Third, the PTM-based camera calibration technique is presented to give an example of pre-1985 camera calibration technique. Fourth, a method is devised to compute the ratio of scale factors. Finally, an optimization scheme is suggested to estimate image center. These modifications preserve all the advantages possessed by the original RAC-based calibration technique. The experiment results are provided to illustrate the effectiveness of the present methods.
Show less - Date Issued
- 1991
- PURL
- http://purl.flvc.org/fcla/dt/14771
- Subject Headings
- Cameras--Calibration
- Format
- Document (PDF)
- Title
- ROBOT CALIBRATION USING STEREO VISION.
- Creator
- CHEN, SHOUPU., Florida Atlantic University, Roth, Zvi S., Sudhakar, Raghavan
- Abstract/Description
-
This thesis deals with a study of using the stereo vision technique in the robot calibration. Three cameras are used in measurement to extract the position information of a target point attached onto each of the robot manipulator links for the purpose of identifying the actual kinematic parameters of every link of the robot manipulator under testing. The robot kinematic model used in this study is the S-Model which is an extension of the well-known Denavit-Hartenberg model. The calibration...
Show moreThis thesis deals with a study of using the stereo vision technique in the robot calibration. Three cameras are used in measurement to extract the position information of a target point attached onto each of the robot manipulator links for the purpose of identifying the actual kinematic parameters of every link of the robot manipulator under testing. The robot kinematic model used in this study is the S-Model which is an extension of the well-known Denavit-Hartenberg model. The calibration has been done on the wrist of the IBM 7565 robot. The experiment set-up and results and the necessary software are all presented in this thesis.
Show less - Date Issued
- 1987
- PURL
- http://purl.flvc.org/fcla/dt/14416
- Subject Headings
- Robotics--Calibration--Measurement
- Format
- Document (PDF)
- Title
- Camera-aided self-calibration of robot manipulators.
- Creator
- Meng, Yan., Florida Atlantic University, Zhuang, Hanqi, College of Engineering and Computer Science, Department of Computer and Electrical Engineering and Computer Science
- Abstract/Description
-
Robot calibration is a software-based accuracy enhancement process. It is normally implemented in a well-controlled environment. However, for a system that function in a natural environment, it is desirable that the system is capable of performing a calibration task without any external expensive calibration apparatus and elaborate setups, i.e., system self-calibration. Vision systems have become standard automation components as cameras are normally integral components of most robotic...
Show moreRobot calibration is a software-based accuracy enhancement process. It is normally implemented in a well-controlled environment. However, for a system that function in a natural environment, it is desirable that the system is capable of performing a calibration task without any external expensive calibration apparatus and elaborate setups, i.e., system self-calibration. Vision systems have become standard automation components as cameras are normally integral components of most robotic manipulators. This research focuses on camera-aided robot self-calibration. Unlike classical vision-based robot calibration methods, which need both image coordinates and precise 3D world coordinates of calibration points, the self-calibration algorithms proposed in the dissertation only require a sequence of images of objects in a natural environment and a known scale. A new robot self-calibration algorithm using a known scale at every camera pose is proposed in the dissertation. It has been known that, the extrinsic parameters of the camera along with its intrinsic parameters can be obtained up to a scale factor by using the corresponding image points of objects due to the factor that the system is inherently under-determined. Now, if the camera is treated as the tool of the robot, one is then able to compute the corresponding robot pose directly from the camera, extrinsic parameters once the scale factor is available. This scale factor, which changes from one camera pose to another, can be uniquely determined from the known scale at each robot pose. The limitation of the above approach for robot self-calibration is that the known scale has to be utilized at every robot measurement pose. A new algorithm is proposed by using the known scale only once in the entire self-calibration procedure. The prerequisite of this calibration algorithm is a carefully planned optimal measurement trajectory for the estimation of the scale factor. By taking into consideration of the observability of the link error parameters, the problem can be formulated either as a constrained or a weighted minimization problem that can be solved by an optimization procedure. A new method for camera lens distortion calibration by using only point correspondences of two images without knowing the camera movement is described in the dissertation. The images for robot calibration can be shared for lens distortion coefficient calibration. This characteristic saves the user much effort in collecting image data and makes it possible to conduct a robot calibration task on line. Extensive simulations and experiment studies on a PUMA 560 robot at FAU Robotics Center reveal the convenience and effectiveness of the proposed self-calibration approaches. Compared to other robot calibration algorithms, the proposed algorithms in this dissertation are more autonomous and can be applied to a natural environment.
Show less - Date Issued
- 2000
- PURL
- http://purl.flvc.org/fcla/dt/12651
- Subject Headings
- Manipulators (Mechanism), Robots--Calibration
- Format
- Document (PDF)
- Title
- KALMAN FILTERING FOR ROBOTIC CALIBRATION.
- Creator
- EL-BALAH, OUSSAMA NAJIB RAWDAH., Florida Atlantic University, Roth, Zvi S.
- Abstract/Description
-
This thesis is concerned with the use of calibration techniques to increase robot accuracy. It is mainly an overview of some of the problems involved in the identification phase of calibration. A robot error model is developed and Kalman filtering algorithm is used in the identification of robot kinematic error parameters. Computer simulations and examples are used to study the behavior of the Kalman filter and its theoretical advantages in robot calibration.
- Date Issued
- 1987
- PURL
- http://purl.flvc.org/fcla/dt/14370
- Subject Headings
- Robotics--Calibration, Kalman filtering
- Format
- Document (PDF)
- Title
- Optimal planning of robot calibration experiments by genetic algorithms.
- Creator
- Huang, Weizhen., Florida Atlantic University, Wu, Jie
- Abstract/Description
-
In this thesis work, techniques developed in the science of genetic computing is applied to solve the problem of planning a robot calibration experiment. Robot calibration is a process by the robot accuracy is enhanced through modification of its control software. The selection of robot measurement configurations is an important element in successfully completing a robot calibration experiment. A classical genetic algorithm is first customized for a type of robot measurement configuration...
Show moreIn this thesis work, techniques developed in the science of genetic computing is applied to solve the problem of planning a robot calibration experiment. Robot calibration is a process by the robot accuracy is enhanced through modification of its control software. The selection of robot measurement configurations is an important element in successfully completing a robot calibration experiment. A classical genetic algorithm is first customized for a type of robot measurement configuration selection problem in which the robot workspace constraints are defined in terms of robot joint limits. The genetic parameters are tuned in a systematic way to greatly enhance the performance of the algorithm. A recruit-oriented genetic algorithm is then proposed, together with new genetic operators. Examples are also given to illustrate the concepts of this new genetic algorithm. This new algorithm is aimed at solving another type of configuration selection problem, in which not all points in the robot workspace are measurable by an external measuring device. Extensive simulation studies are conducted for both classical and recruit-oriented genetic algorithms, to examine the effectiveness of these algorithms.
Show less - Date Issued
- 1995
- PURL
- http://purl.flvc.org/fcla/dt/15186
- Subject Headings
- Genetic algorithms, Robots--Calibration, Combinatorial optimization
- Format
- Document (PDF)
- Title
- Synthesis of vision-based robot calibration using moving cameras.
- Creator
- Wang, Kuanchih., Florida Atlantic University, Roth, Zvi S., Zhuang, Hanqi, College of Engineering and Computer Science, Department of Computer and Electrical Engineering and Computer Science
- Abstract/Description
-
Robot calibration using a vision system and moving cameras is the focus of this dissertation. The dissertation contributes in the areas of robot modeling, kinematic identification and calibration measurement. The effects of perspective distortion of circular camera calibration points is analyzed. A new modified complete and parametrically continuous robot kinematic model, an evolution of the complete and parametrically continuous (CPC) model, is proposed. It is shown that the model's error...
Show moreRobot calibration using a vision system and moving cameras is the focus of this dissertation. The dissertation contributes in the areas of robot modeling, kinematic identification and calibration measurement. The effects of perspective distortion of circular camera calibration points is analyzed. A new modified complete and parametrically continuous robot kinematic model, an evolution of the complete and parametrically continuous (CPC) model, is proposed. It is shown that the model's error-model can be developed easily as the structure of this new model is very simple and similar to the Denavit-Hartenbert model. The derivation procedure of the error-model follows a systematic method that can be applied to any kind of robot arms. Pose measurement is the most crucial step in robot calibration. The use of stereo as well as mono mobile camera measurement system for collection of pose data of the robot end-effector is investigated. The Simulated Annealing technique is applied to the problem of optimal measurement configuration selection. Joint travel limits can be included in the cost function. It is shown that trapping into local minimum points can be effectively avoided by properly choosing an initial point and a temperature schedule. The concept of simultaneous calibration of camera and robot is developed and implemented as an automated process that determines the system model parameters using only the system's internal sensors. This process uses a unified mathematical model for the entire robot/camera system. The results of the kinematic identification, optimal configuration selection, and simultaneous calibration of robot and camera using the PUMA 560 robot arm have demonstrated that the modified complete and parametrically continuous model is a viable and simple modeling tool, which can achieve desired accuracy. The systematic way of modeling and performing of different kinds of vision-based robot applications demonstrated in this dissertation will pave the way for industrial standardizing of robot calibration done by the robot user on the manufacturing floor.
Show less - Date Issued
- 1993
- PURL
- http://purl.flvc.org/fcla/dt/12339
- Subject Headings
- Robot vision, Robot cameras--Calibration
- Format
- Document (PDF)
- Title
- Camera-aided SCARA arm calibration.
- Creator
- Wu, Wen-chiang., Florida Atlantic University, Zhuang, Hanqi, College of Engineering and Computer Science, Department of Computer and Electrical Engineering and Computer Science
- Abstract/Description
-
The focus of this thesis is the kinematic calibration of a SCARA arm with a hand-mounted camera. Kinematic calibration can greatly improve the accuracy of SCARA arms, which are widely used in electronic assembly lines. Vision-based robot calibration has the potential of being a fast, nonintrusive, low-cost, and autonomous approach. In this thesis, we apply a vision-based technique to calibrate SCARA arms. The robot under investigation is modeled by the modified complete and parametrically...
Show moreThe focus of this thesis is the kinematic calibration of a SCARA arm with a hand-mounted camera. Kinematic calibration can greatly improve the accuracy of SCARA arms, which are widely used in electronic assembly lines. Vision-based robot calibration has the potential of being a fast, nonintrusive, low-cost, and autonomous approach. In this thesis, we apply a vision-based technique to calibrate SCARA arms. The robot under investigation is modeled by the modified complete and parametrically continuous model. By repeatedly calibrating the camera, the pose of the robot end-effector are collected at various robot measurement configurations. A least squares technique is then applied to estimate the geometric error parameters of the SCARA arm using the measured robot poses. In order to improve the robustness of the method, a new approach is proposed to calibrate the hand-mounted camera. The calibration algorithm is designed to deal with the case in which the camera sensor plane is nearly-parallel to the camera calibration board. Practical issues regarding robot calibration in general and SCARA arm calibration in particular are also addressed. Experiment studies reveal that the proposed camera-aided approach is a viable means for accuracy enhancement of SCARA arms.
Show less - Date Issued
- 1994
- PURL
- http://purl.flvc.org/fcla/dt/15075
- Subject Headings
- Robots--Calibration, Manipulators (Mechanism)--Calibration, Robots--Error detection and recovery, Image processing
- Format
- Document (PDF)
- Title
- Statistical Correlation between DMSP-OLS Night Light Images and Economic Activity at the MSA Level in Florida.
- Creator
- Forbes, Dolores J., Roberts, Charles, Graduate College
- Date Issued
- 2011-04-08
- PURL
- http://purl.flvc.org/fcla/dt/3172435
- Subject Headings
- Pyrometers--Calibration, National Geophysical Data Center, Gross domestic product
- Format
- Document (PDF)
- Title
- Optimization of Computed Tomography Calibration Curve for Proton Therapy Treatment Planning.
- Creator
- Ghasemi Ghonchehnazi, Maryam, Shang, Charles, Leventouri, Theodora, Florida Atlantic University, Department of Physics, Charles E. Schmidt College of Science
- Abstract/Description
-
The accuracy of proton dose computation in the treatment planning system relies on the conversion from the Hounsfield units (HU) of each voxel in the patient CT scan to the proton stopping power ratio (SPR). The aim of this study is to investigate the potential improvement in determining proton SPR using single energy computed tomography (SECT) to reduce the uncertainty in predicting the proton range in patients. Factors which may cause CT number variations in the calibration curve have been...
Show moreThe accuracy of proton dose computation in the treatment planning system relies on the conversion from the Hounsfield units (HU) of each voxel in the patient CT scan to the proton stopping power ratio (SPR). The aim of this study is to investigate the potential improvement in determining proton SPR using single energy computed tomography (SECT) to reduce the uncertainty in predicting the proton range in patients. Factors which may cause CT number variations in the calibration curve have been examined. The HU-SPR calibration curve was determined based on HU of human body tissues using the stoichiometric method. The uncertainties in SPR were divided into two major categories: The inherent uncertainty, and the CT number uncertainty. The root mean square errors of the inherent uncertainties were estimated 0.02%, 0.61% and 0.26% for lung tissues, soft tissues (excluding Thyroid), and bone tissues, respectively. The total uncertainties due to the inherent uncertainty and CT imaging errors were estimated 1.50%. The average calibration curve of two sized phantoms (head and body) were used in the treatment planning system to mitigate beam hardening effect through the attenuating media. A higher accuracy of the SPR prediction using the stoichiometric method is suggested through comparison with the predicted SPRs that derived from the direct calibration approach.
Show less - Date Issued
- 2019
- PURL
- http://purl.flvc.org/fau/fd/FA00013374
- Subject Headings
- Proton Therapy, Tomography, Calibration, Tomography, X-Ray Computed
- Format
- Document (PDF)
- Title
- Design and implementation of a control system for a laser-tracking measurement system.
- Creator
- Bai, Ying., Florida Atlantic University, Roth, Zvi S., Zhuang, Hanqi, College of Engineering and Computer Science, Department of Computer and Electrical Engineering and Computer Science
- Abstract/Description
-
To assess and evaluate the performance of robots and machine tools dynamically, it is desirable to have a precision measuring device that performs dynamic measurement of end-effector positions of such robots and machine tools. Among possible measurement techniques, Laser Tracking Systems (LTSs) exlnbit the capability of high accuracy, large workspace, high sampling rate, and automatic target-tracking,. and thus are well-suited for robot calibration both kinematically and dynamically. In this...
Show moreTo assess and evaluate the performance of robots and machine tools dynamically, it is desirable to have a precision measuring device that performs dynamic measurement of end-effector positions of such robots and machine tools. Among possible measurement techniques, Laser Tracking Systems (LTSs) exlnbit the capability of high accuracy, large workspace, high sampling rate, and automatic target-tracking,. and thus are well-suited for robot calibration both kinematically and dynamically. In this dissertation, the design and implementation of a control system for a homemade laser tracking measurement systems is addressed and calibration of a robot using the laser tracking system is demonstrated Design and development of a control system for a LTS is a challenging task. It involves a deep understanding of laser interferometry,. controls, mechanics and optics,. both in theoretical perspective and in implementation aspect. One of the most important requirements for a successful design and implementation of a control system for the LTS is proper installation and alignment of the laser and optical system,. or laser transducer system. The precision of measurement using the LTS depends highly on the accuracy of the laser transducer system, as well as the accuracy of the installation and alignment of the optical system. Hence, in reference to the experimental alignment method presented in this dissertation, major error sources affecting the system measurement accuracy are identified and analyzed. A manual compensation method is developed to eliminate the effects of these error sources effectively in the measurement system. Considerations on proper design and installation of laser and optical components are indicated in this dissertation. As a part of the conventional control system design, a dynamic system model of the LTS is required. In this study, a detailed derivation and analysis of the dynamic model of the motor gimbal system using Lagrange-Euler equations of motion is developed for both ideal and complete gimbal systems. Based on this system model,. a conventional controller is designed. Fuzzy Logic Controllers (FLC) are designed in order to suppress noise or disturbances that exist in the motor driver subsystem. By using the relevant control strategies. noise and disturbances present in the electrical control channels are shown to reduce significantly. To improve the system performance further, a spectrum analysis of the error sources and disturbances existing in the system is conducted. Major noise sources are effectively suppressed by using a two-stage fuzzy logic control strategy. A comparison study on the performances of different control strategies is given in this dissertation, in reference to the following: An ideal system model, a system with a long time delay, a system with various noise sources and a system model with uncertainties. Both simulation and experimental results are furnished to illustrate the advantages of the FLC in respect of its transient response, steady-state response, and tracking performance. Furthermore, noise reduction in the laser tracking system is demonstrated. Another important issue concerning a successful application of the LTS in the calibration of a robot is the estimation of system accuracy. Hence, a detailed analysis of system accuracy of the LTS is presented in this worL This analysis is also verified by experimental methods by means of tracking a Coordinate Measuring Machine available in the FAU Robotics Center. Using the developed LTS, a PUMA robot in the FAU Robotics Center is calibrated. The results obtained are confirmative with the data available in the literature. In summary, the proposed methodology towards the design and implementation of a control system for LTSs has been shown to be successful by performing experimental tracking and calibration studies at the FAU Robotics Center.
Show less - Date Issued
- 2000
- PURL
- http://purl.flvc.org/fcla/dt/12622
- Subject Headings
- Robots--Calibration, Robots--Control systems, Fuzzy logic
- Format
- Document (PDF)
- Title
- Workspace evaluation and kinematic calibration of Stewart platform.
- Creator
- Wang, Jian., Florida Atlantic University, Masory, Oren, Roth, Zvi S., College of Engineering and Computer Science, Department of Computer and Electrical Engineering and Computer Science
- Abstract/Description
-
Parallel manipulators have their special characteristics in contrast to the traditional serial type of robots. Stewart platform is a typical six degree of freedom fully parallel robot manipulator. The goal of this research is to enhance the accuracy and the restricted workspace of the Stewart platform. The first part of the dissertation discusses the effect of three kinematic constraints: link length limitation, joint angle limitation and link interference, and kinematic parameters on the...
Show moreParallel manipulators have their special characteristics in contrast to the traditional serial type of robots. Stewart platform is a typical six degree of freedom fully parallel robot manipulator. The goal of this research is to enhance the accuracy and the restricted workspace of the Stewart platform. The first part of the dissertation discusses the effect of three kinematic constraints: link length limitation, joint angle limitation and link interference, and kinematic parameters on the workspace of the platform. An algorithm considering the above constraints for the determination of the volume and the envelop of Stewart platform workspace is developed. The workspace volume is used as a criterion to evaluate the effects of the platform dimensions and kinematic constraints on the workspace and the dexterity of the Stewart platform. The analysis and algorithm can be used as a design tool to select dimensions, actuators and joints in order to maximize the workspace. The remaining parts of the dissertation focus on the accuracy enhancement. Manufacturing tolerances, installation errors and link offsets cause deviations with respect to the nominal parameters of the platform. As a result, if nominal parameters are being used, the resulting platform pose will be inaccurate. An accurate kinematic model of Stewart platform which accommodates all manufacturing and installation errors is developed. In order to evaluate the effects of the above factors on the accuracy, algorithms for the forward and inverse kinematics solutions of the accurate model are developed. The effects of different manufacturing tolerances and installation errors on the platform accuracy are investigated based on this model. Simulation results provide insight into the expected accuracy and indicate the major factors contributing to the inaccuracies. In order to enhance the accuracy, there is a need to calibrate the platform, or to determine the actual values of the kinematic parameters (Parameter Identification) and to incorporate these into the inverse kinematic solution (Accuracy Compensation). An error-model based algorithm for the parameter identification is developed. Procedures for the formulation of the identification Jacobian and for accuracy compensation are presented. The algorithms are tested using simulated measurements in which the realistic measurement noise is included. As a result, pose error of the platform are significantly reduced.
Show less - Date Issued
- 1992
- PURL
- http://purl.flvc.org/fcla/dt/12316
- Subject Headings
- Robots--Control systems, Manipulators (Mechanism), Robotics--Calibration
- Format
- Document (PDF)
- Title
- The visual looming navigation cue: A unified approach.
- Creator
- Joarder, Kunal., Florida Atlantic University, Raviv, Daniel, College of Engineering and Computer Science, Department of Computer and Electrical Engineering and Computer Science
- Abstract/Description
-
This research introduces a unified approach to visual looming. Visual looming is related to an increasing projected size of an object on a viewer's retina while the relative distance between the viewer and the object decreases. Psychophysicists and neurobiologists have studied this phenomenon by observing vision and action in unison and have reported subject's tendency to react defensively or using this information in an anticipatory control of the body. Since visual looming induces senses of...
Show moreThis research introduces a unified approach to visual looming. Visual looming is related to an increasing projected size of an object on a viewer's retina while the relative distance between the viewer and the object decreases. Psychophysicists and neurobiologists have studied this phenomenon by observing vision and action in unison and have reported subject's tendency to react defensively or using this information in an anticipatory control of the body. Since visual looming induces senses of threat of collision, the same cue, if quantified, can be used along with visual fixation in obstacle avoidance in mobile robots. In quantitative form visual looming is defined as the time derivative of the relative distance (range) between the observer and the object divided by the relative distance itself. The visual looming is a measurable variable. Following the paradigm of Active Vision the approach in this research uses visual fixation to selectively attend a small part of the image, that is relevant to the task. Visual looming provides a time-based mapping from a "set of 2-D image cues" to "time-based 3-D space". This research describes how visual looming, which is a concept related to an object in the 3-D world, can be calculated studying the relative temporal change in the following four different attributes of a sequence of 2-D images: (i) image area; (ii) image brightness; (iii) texture density in the image; (iv) image blur. From a simple closed form expression it shows that a powerful unified approach can be adopted in these methods. An extension of this unified approach establishes a strong relationship with the Weber-Fechner law in Psychophysics. The four different methods explored for the calculation of looming are simple. The experimental results illustrate how the measured values of looming stay close to the actual values. This research also introduces one important visual invariant $\Re$ that exists in relative movements between a camera light-source pair and a visible object. Finally, looming is used in the sense of a threat of collision, to navigate in an unknown environment. The results show that the approach can be used in real-time obstacle avoidance with very little a-priori knowledge.
Show less - Date Issued
- 1995
- PURL
- http://purl.flvc.org/fcla/dt/12416
- Subject Headings
- Robots--Control systems, Robot vision, Robot camera--Calibration
- Format
- Document (PDF)
- Title
- Self-calibration of parallel-link mechanisms.
- Creator
- Liu, Lixin., Florida Atlantic University, Zhuang, Hanqi, College of Engineering and Computer Science, Department of Computer and Electrical Engineering and Computer Science
- Abstract/Description
-
Self-calibration is a desirable feature for an intelligent machine such as a robot that must function outside of controlled laboratory conditions. This is because it is inevitable that variations in the kinematic model arise from imperfections in the manufacturing process and changes of environment conditions. Self-calibration has the potential of (a) removing the dependence on external pose sensing, (b) producing high accuracy measurement data over the entire workspace of the system with an...
Show moreSelf-calibration is a desirable feature for an intelligent machine such as a robot that must function outside of controlled laboratory conditions. This is because it is inevitable that variations in the kinematic model arise from imperfections in the manufacturing process and changes of environment conditions. Self-calibration has the potential of (a) removing the dependence on external pose sensing, (b) producing high accuracy measurement data over the entire workspace of the system with an extremely fast measurement rate, (c) being automated and completely non invasive, (d) facilitating on-line accuracy compensation, and (e) being cost effective. This dissertation concentrates on the study of self-calibrating parallel-link mechanisms. A framework of self-calibration of a parallel-link mechanism is created, which is based on kinematic analysis and the construction of measurement residuals utilizing the information provided by redundant sensors embedded in the system. Forward and inverse kinematic measurement residuals of the mechanisms are proposed. To avoid the estimation of redundant kinematic parameters of the mechanism, the concept of relative residuals is introduced. Guidelines for placement of sensors for self-calibration are presented. An approach to determining the number of independent kinematic parameters of the mechanism is introduced. Extensive simulation and experimental studies conducted on a parallel-link mechanism, the Stewart platform built in the Robotics Center at Florida Atlantic University, confirm the effectiveness of the proposed approach.
Show less - Date Issued
- 1997
- PURL
- http://purl.flvc.org/fcla/dt/12539
- Subject Headings
- Manipulators (Mechanism)--Calibration, Robots--Control systems, Robotics
- Format
- Document (PDF)
- Title
- Design and development of an autocalibrating radiometer for deep sea biooptical studies.
- Creator
- Widder, Edith A., Caimi, F. M., Taylor, Lawrence D., Tusting, Robert F.
- Date Issued
- 1992
- PURL
- http://purl.flvc.org/FCLA/DT/3351950
- Subject Headings
- Radiometers, Radiometers--Design and construction, Underwater light--Measurement, Radiometers--Calibration
- Format
- Document (PDF)
- Title
- Self-calibration of laser tracking measurement system with planar constraints.
- Creator
- Motaghedi, Shui Hu., Florida Atlantic University, Zhuang, Hanqi, Roth, Zvi S., College of Engineering and Computer Science, Department of Computer and Electrical Engineering and Computer Science
- Abstract/Description
-
Laser tracking coordinate measuring machines have the potential of continuously measuring three dimensional target coordinates in a large workspace with a fast sampling rate and high accuracy. Proper calibration of a laser tracking measurement system is essential prior to use of such a device for metrology. In the absence of a more accurate instrument for system calibration, one has to rely on self-calibration strategies. In this dissertation, a kinematic model that describes not only the...
Show moreLaser tracking coordinate measuring machines have the potential of continuously measuring three dimensional target coordinates in a large workspace with a fast sampling rate and high accuracy. Proper calibration of a laser tracking measurement system is essential prior to use of such a device for metrology. In the absence of a more accurate instrument for system calibration, one has to rely on self-calibration strategies. In this dissertation, a kinematic model that describes not only the motion but also geometric variations of a multiple-beam laser tracking system was developed. The proposed model has the following features: (1) Target positions can be computed from both distance and angular measurements. (2) Through error analysis it was proven that even rough angular measurement may improve the overall system calibration results. A self-calibration method was proposed to calibrate intelligent machines with planar constraints. The method is also applied to the self-calibration of the laser tracking system and a standard PUMA 560 robot. Various calibration strategies utilizing planar constraints were explored to deal with different system setups. For each calibration strategy, issues about the error parameter estimation of the system were investigated to find out under which conditions these parameters can be uniquely estimated. These conditions revealed the applicability of the planar constraints to the system self-calibration. The observability conditions can serve as a guideline for the experimental setup when planar constraint is utilized in the machine calibration including the calibration of the laser tracking systems. Intensive simulation studies were conducted to check validity of the theoretical results. Realistic noise values were injected to the system models to statistically assess the behavior of the self-calibration system under real-world conditions. Various practical calibration issues were also explored in the simulations and therefore to pave ways for experimental investigation. The calibration strategies were also applied experimentally to calibrate a laser tracking system constructed at the Robotics Center in Florida Atlantic University.
Show less - Date Issued
- 1999
- PURL
- http://purl.flvc.org/fcla/dt/12599
- Subject Headings
- Robots--Kinematics, Robotics--Calibration--Measurement, Robots--Control systems
- Format
- Document (PDF)
- Title
- Development of a graphical user interface for a Stewart platform.
- Creator
- Subramanian, Chenthilvel Muthukumaran., Florida Atlantic University, Masory, Oren, College of Engineering and Computer Science, Department of Ocean and Mechanical Engineering
- Abstract/Description
-
A user friendly graphical interface was developed to control a Stewart platform which is a six degree-of-freedom in-parallel mechanism. The interface allows the user to define the platform motion relative to various coordinate systems: base, platform and joint. The velocity/position reference to the platform's controller can be provided by the following ways: preprogrammed data file, serial communication RS-232, 6 degrees of freedom joystick and soft teach pendant. The platform was designed...
Show moreA user friendly graphical interface was developed to control a Stewart platform which is a six degree-of-freedom in-parallel mechanism. The interface allows the user to define the platform motion relative to various coordinate systems: base, platform and joint. The velocity/position reference to the platform's controller can be provided by the following ways: preprogrammed data file, serial communication RS-232, 6 degrees of freedom joystick and soft teach pendant. The platform was designed to be used as "Space Emulator" and therefore a 6 degrees of freedom force/torque sensor was needed. Two different models of such sensors were designed and analyzed using finite element analysis techniques. Based on the results one particular model was selected, fabricated, instrumented with strain gages and calibrated in order to obtain its stiffness matrix. The effect of drifting of the sensor output due to self heating of the strain gages and the electronic components of the strain gage amplifiers was also studied.
Show less - Date Issued
- 1993
- PURL
- http://purl.flvc.org/fcla/dt/14941
- Subject Headings
- Robots--Control systems, Robotics--Calibration, Manipulators (Mechanism), Finite element method, Graphical user interfaces (Computer systems)
- Format
- Document (PDF)