You are here
Effect of steel reinforcement type and surface condition on corrosion initiation in mortar
- Date Issued:
- 2003
- Summary:
- This study employed half-cell potential (Eoc), polarization resistance (PR) and galvanic current tests to explore effects of surface condition and steel reinforcement type on corrosion initiation in mortar. A low impurity steel plate and #10 grade 60 rebar were used. Four surface conditions (as-received, atmospherically rusted, #240 SiC paper polished, and #500 SiC paper polished) were employed. Cyclic wet and dry exposure of specimens in 15% NaCl solution was conducted. Half-cell potential measurements showed that the corrosion probability of specimens with as-received and pre-rusted surfaces was lower than that of specimens with a polished surface. However, the PR and galvanic current tests indicated higher corrosion rate for specimens prepared with atmospherically rusted and as-received steels. Good agreement was found between results of the polarization resistance test and galvanic current measurements. There is a lack of correlation between half-cell potential and corrosion rate.
Title: | Effect of steel reinforcement type and surface condition on corrosion initiation in mortar. |
107 views
53 downloads |
---|---|---|
Name(s): |
Huang, Yirong. Florida Atlantic University, Degree grantor Hartt, William H., Thesis advisor |
|
Type of Resource: | text | |
Genre: | Electronic Thesis Or Dissertation | |
Issuance: | monographic | |
Date Issued: | 2003 | |
Publisher: | Florida Atlantic University | |
Place of Publication: | Boca Raton, Fla. | |
Physical Form: | application/pdf | |
Extent: | 72 p. | |
Language(s): | English | |
Summary: | This study employed half-cell potential (Eoc), polarization resistance (PR) and galvanic current tests to explore effects of surface condition and steel reinforcement type on corrosion initiation in mortar. A low impurity steel plate and #10 grade 60 rebar were used. Four surface conditions (as-received, atmospherically rusted, #240 SiC paper polished, and #500 SiC paper polished) were employed. Cyclic wet and dry exposure of specimens in 15% NaCl solution was conducted. Half-cell potential measurements showed that the corrosion probability of specimens with as-received and pre-rusted surfaces was lower than that of specimens with a polished surface. However, the PR and galvanic current tests indicated higher corrosion rate for specimens prepared with atmospherically rusted and as-received steels. Good agreement was found between results of the polarization resistance test and galvanic current measurements. There is a lack of correlation between half-cell potential and corrosion rate. | |
Identifier: | 9780496219131 (isbn), 13075 (digitool), FADT13075 (IID), fau:9939 (fedora) | |
Collection: | FAU Electronic Theses and Dissertations Collection | |
Note(s): |
College of Engineering and Computer Science Thesis (M.S.)--Florida Atlantic University, 2003. |
|
Subject(s): |
Corrosion and anti-corrosives--Testing Reinforced concrete--Corrosion Mortar Steel--Corrosion |
|
Held by: | Florida Atlantic University Libraries | |
Persistent Link to This Record: | http://purl.flvc.org/fcla/dt/13075 | |
Sublocation: | Digital Library | |
Use and Reproduction: | Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder. | |
Use and Reproduction: | http://rightsstatements.org/vocab/InC/1.0/ | |
Host Institution: | FAU | |
Is Part of Series: | Florida Atlantic University Digital Library Collections. |