An Algorithm to Determine IMRT Optimization Parameters within the Elekta Monaco® Treatment Planning System that Increases Dose Homogeneity and Dose Conformity in the Planning Target Volume
- Date Issued:
- 2022
- Abstract/Description:
- An algorithm to determine IMRT optimization parameters within the Elekta Monaco® treatment planning system that increases dose homogeneity and dose conformity in the planning target volume was developed. This algorithm determines IMRT optimization parameters by calculating the difference between two pairs of dose points along the target volume’s dose volume histogram: Dmax – Dmin, and D2 – D98. The algorithm was tested on the Elekta Monaco® Treatment Planning System at GenesisCare of Coconut Creek, Florida using CT data from 10 anonymized patients with non-small cell lung cancer of various tumor sizes and locations. Nine iterations of parameters were tested on each patient. Once the ideal parameters were found, the results were evaluated using the ICRU report 83 homogeneity index as well as the Paddick conformity index. As an outcome of this research, it is recommended that at least three iterations of IMRT optimization parameters should be calculated to find the ideal parameters.
Title: | An Algorithm to Determine IMRT Optimization Parameters within the Elekta Monaco® Treatment Planning System that Increases Dose Homogeneity and Dose Conformity in the Planning Target Volume. |
106 views
44 downloads |
---|---|---|
Name(s): |
Gregorisch, David , author Pella, Silvia , Thesis advisor Kyriacou, Andreas , Thesis advisor Florida Atlantic University, Degree grantor Department of Physics Charles E. Schmidt College of Science |
|
Type of Resource: | text | |
Genre: | Electronic Thesis Or Dissertation | |
Date Created: | 2022 | |
Date Issued: | 2022 | |
Publisher: | Florida Atlantic University | |
Place of Publication: | Boca Raton, Fla. | |
Physical Form: | application/pdf | |
Extent: | 125 p. | |
Language(s): | English | |
Abstract/Description: | An algorithm to determine IMRT optimization parameters within the Elekta Monaco® treatment planning system that increases dose homogeneity and dose conformity in the planning target volume was developed. This algorithm determines IMRT optimization parameters by calculating the difference between two pairs of dose points along the target volume’s dose volume histogram: Dmax – Dmin, and D2 – D98. The algorithm was tested on the Elekta Monaco® Treatment Planning System at GenesisCare of Coconut Creek, Florida using CT data from 10 anonymized patients with non-small cell lung cancer of various tumor sizes and locations. Nine iterations of parameters were tested on each patient. Once the ideal parameters were found, the results were evaluated using the ICRU report 83 homogeneity index as well as the Paddick conformity index. As an outcome of this research, it is recommended that at least three iterations of IMRT optimization parameters should be calculated to find the ideal parameters. | |
Identifier: | FA00013990 (IID) | |
Degree granted: | Thesis (PMS)--Florida Atlantic University, 2022. | |
Collection: | FAU Electronic Theses and Dissertations Collection | |
Note(s): | Includes bibliography. | |
Subject(s): |
Radiotherapy Algorithm Medical physics |
|
Persistent Link to This Record: | http://purl.flvc.org/fau/fd/FA00013990 | |
Use and Reproduction: | Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder. | |
Use and Reproduction: | http://rightsstatements.org/vocab/InC/1.0/ | |
Host Institution: | FAU | |
Is Part of Series: | Florida Atlantic University Digital Library Collections. |